跳至主導覽 跳至搜尋 跳過主要內容

Volumetric modulated arc therapy for nasopharyngeal carcinoma: A dosimetric comparison with TomoTherapy and step-and-shoot IMRT

  • Szu Huai Lu
  • , Jason Chia Hsien Cheng
  • , Sung Hsin Kuo
  • , Jason Jeun Shenn Lee
  • , Liang Hsin Chen
  • , Jian Kuen Wu
  • , Yu Hsuan Chen
  • , Wan Yu Chen
  • , Shu Yu Wen
  • , Fok Ching Chong
  • , Chien Jang Wu
  • , Chun Wei Wang*
  • *此作品的通信作者

研究成果: 雜誌貢獻期刊論文同行評審

107   連結會在新分頁中打開 引文 斯高帕斯(Scopus)

摘要

Purpose: Volumetric modulated arc therapy (VMAT), a novel technique, employs a linear accelerator to conduct dynamic modulation rotation radiotherapy. The goal of this study was to compare VMAT with helical tomotherapy (HT) and step-and-shoot intensity-modulated radiation therapy (IMRT) for nasopharyngeal carcinoma (NPC) patients with regard to the sparing effect on organs at risk (OARs), dosimetric quality, and efficiency of delivery. Materials and methods: Twenty patients with NPC treated by HT were re-planned by VMAT (two arcs) and IMRT (7-9 fields) for dosimetric comparison. The target area received three dose levels (70, 60, and 54 Gy) in 33 fractions using simultaneous integrated boosts technique. The Philips Pinnacle Planning System 9.0 was adopted to design VMAT, using SmartArc as the planning algorithm. For a fair comparison, the planning target volume (PTV) coverage of the 3 plans was normalized to the same level. Dosimetric comparisons between VMAT, HT, and IMRT plans were analyzed to evaluate (1) coverage, homogeneity, and conformity of PTV, (2) sparing of OARs, (3) delivery time, and (4) monitor units (MUs). Results: The VMAT, HT, and IMRT plans had similar PTV coverage with an average of 96%. There was no significant difference between VMAT and HT in homogeneity, while the homogeneity indices of VMAT (1.06) and HT (1.06) were better than IMRT plans (1.07, p < 0.05). HT plans provided a better conformity index (1.17) than VMAT (1.28, p = 0.01) and IMRT (1.36, p = 0.02). When compared with IMRT, VMAT and HT had a better sparing effect on brain stem and spinal cord (p < 0.05). The effect of parotid sparing was similar between VMAT (mean = 26.3 Gy) and HT (mean = 27.5 Gy), but better than IMRT (mean = 31.3 Gy, p < 0.01). The delivery time per fraction for VMAT (5.7 min) were much lower than for HT (9.5 min, p < 0.01) and IMRT (9.2 min, p < 0.01). Conclusions: Our results indicate that VMAT provides better sparing of normal tissue, homogeneity, and conformity than IMRT, and shorter delivery time than HT.

原文英語
頁(從 - 到)324-330
頁數7
期刊Radiotherapy and Oncology
104
發行號3
DOIs
出版狀態已發佈 - 2012 9月

ASJC Scopus subject areas

  • 血液學
  • 腫瘤科
  • 放射學、核子醫學和影像學

指紋

深入研究「Volumetric modulated arc therapy for nasopharyngeal carcinoma: A dosimetric comparison with TomoTherapy and step-and-shoot IMRT」主題。共同形成了獨特的指紋。

引用此