TY - JOUR
T1 - Streamlining regular liquid chromatography with MALDI-TOF MS and NMR spectroscopy using automatic full-contact splitless spotting interface and flash-tap fractioning collection
AU - Truong, Chi Minh
AU - Jair, Yung Cheng
AU - Chen, Hong Po
AU - Chen, Wei Chih
AU - Liu, Yi Hsin
AU - Chen, Pin Chuan
AU - Chen, Pai Shan
N1 - Publisher Copyright:
© 2024 Elsevier B.V.
PY - 2024/4/15
Y1 - 2024/4/15
N2 - Background: High-resolution matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) and nuclear magnetic resonance (NMR) spectroscopy are powerful tools to identify unknown psychoactive substances. However, in complex matrices, trace levels of unknown substances usually require additional fractionation and concentration. Specialized liquid chromatography systems are necessary for both techniques. The small flow rate of nano LC, typically paired with MALDI-TOF MS, often results in prolonged fractionation times. Conversely, the larger flow rate of semi-preparative LC, used for NMR analysis, can be time-consuming and labor-intensive when concentrating samples. To address these issues, we developed an integrated automatic system that integrated to regular LC. Result: Automatic spot collector (ASC) and automatic fraction collector (AFC) were present in this study. The ASC utilized in-line matrix mixing, full-contact spotting and real time heating (50 °C), achieving great capacity of 5 μL droplet on MALDI plate, high recovery (76–116%) and rapid evaporation in 2 min. The analytes were concentrated 4–8 times, forming even crystallization, reaching the detection limit at the concentration of 50 μg L−1 for 12 psychoactive substances in urine. The AFC utilizes flexible tubing which flash-tapped the microtube's upper rim (3 mm depth) instead of reaching the bottom. This method prevents sample loss and minimizes the robotic arm's movement, providing a high fractionating speed at 6 s 12 psychoactive compounds were fractionated in a single round analysis (recovery: 81%–114%). Methamphetamine and nitrazepam obtained from drug-laced coffee samples were successful analyzed with photodiode array (PDA) after one AFC round and NMR after five rounds. Significance: The ASC device employed real-time heating, in-line matrix mixing, and full-contact spotting to facilitate the samples spotting onto the MALDI target plate, thereby enhancing detection sensitivity in low-concentration and complex samples. The AFC device utilized the novel flash-tapping method to achieve rapid fractionation and high recovery rate. These devices were assembled using commercially available components, making them affordable (400 USD) for most laboratories while still meeting the required performance for advanced commercialized systems.
AB - Background: High-resolution matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) and nuclear magnetic resonance (NMR) spectroscopy are powerful tools to identify unknown psychoactive substances. However, in complex matrices, trace levels of unknown substances usually require additional fractionation and concentration. Specialized liquid chromatography systems are necessary for both techniques. The small flow rate of nano LC, typically paired with MALDI-TOF MS, often results in prolonged fractionation times. Conversely, the larger flow rate of semi-preparative LC, used for NMR analysis, can be time-consuming and labor-intensive when concentrating samples. To address these issues, we developed an integrated automatic system that integrated to regular LC. Result: Automatic spot collector (ASC) and automatic fraction collector (AFC) were present in this study. The ASC utilized in-line matrix mixing, full-contact spotting and real time heating (50 °C), achieving great capacity of 5 μL droplet on MALDI plate, high recovery (76–116%) and rapid evaporation in 2 min. The analytes were concentrated 4–8 times, forming even crystallization, reaching the detection limit at the concentration of 50 μg L−1 for 12 psychoactive substances in urine. The AFC utilizes flexible tubing which flash-tapped the microtube's upper rim (3 mm depth) instead of reaching the bottom. This method prevents sample loss and minimizes the robotic arm's movement, providing a high fractionating speed at 6 s 12 psychoactive compounds were fractionated in a single round analysis (recovery: 81%–114%). Methamphetamine and nitrazepam obtained from drug-laced coffee samples were successful analyzed with photodiode array (PDA) after one AFC round and NMR after five rounds. Significance: The ASC device employed real-time heating, in-line matrix mixing, and full-contact spotting to facilitate the samples spotting onto the MALDI target plate, thereby enhancing detection sensitivity in low-concentration and complex samples. The AFC device utilized the novel flash-tapping method to achieve rapid fractionation and high recovery rate. These devices were assembled using commercially available components, making them affordable (400 USD) for most laboratories while still meeting the required performance for advanced commercialized systems.
KW - Automation
KW - Fractioning and spotting
KW - Liquid chromatography
KW - Matrix-assisted laser desorption/ionization-time of flight-mass spectrometry
KW - Nuclear magnetic resonance spectroscopy
UR - http://www.scopus.com/inward/record.url?scp=85186533162&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85186533162&partnerID=8YFLogxK
U2 - 10.1016/j.aca.2024.342401
DO - 10.1016/j.aca.2024.342401
M3 - Article
C2 - 38462340
AN - SCOPUS:85186533162
SN - 0003-2670
VL - 1298
JO - Analytica Chimica Acta
JF - Analytica Chimica Acta
M1 - 342401
ER -