TY - JOUR
T1 - Spatial repolarization heterogeneity detected by magnetocardiography correlates with cardiac iron overload and adverse cardiac events in beta-thalassemia major
AU - Chen, Chun An
AU - Lu, Meng Yao
AU - Peng, Shinn Forng
AU - Lin, Kai Hsin
AU - Chang, Hsiu Hao
AU - Yang, Yung Li
AU - Jou, Shiann Tarng
AU - Lin, Dong Tsamn
AU - Liu, Yen Bin
AU - Horng, Herng Er
AU - Yang, Hong Chang
AU - Wang, Jou Kou
AU - Wu, Mei Hwan
AU - Wu, Chau Chung
PY - 2014/1/27
Y1 - 2014/1/27
N2 - Background: Patients with transfusion-dependent beta-thalassemia major (TM) are at risk for myocardial iron overload and cardiac complications. Spatial repolarization heterogeneity is known to be elevated in patients with certain cardiac diseases, but little is known in TM patients. The purpose of this study was to evaluate spatial repolarization heterogeneity in patients with TM, and to investigate the relationships between spatial repolarization heterogeneity, cardiac iron load, and adverse cardiac events. Methods and Results: Fifty patients with TM and 55 control subjects received 64-channel magnetocardiography (MCG) to determine spatial repolarization heterogeneity, which was evaluated by a smoothness index of QTc (SI-QTc), a standard deviation of QTc (SD-QTc), and a QTc dispersion. Left ventricular function and myocardial T2* values were assessed by cardiac magnetic resonance. Patients with TM had significantly greater SI-QT c, SD-QTc, and QTc dispersion compared to the control subjects (all p values<0.001). Spatial repolarization heterogeneity was even more pronounced in patients with significant iron overload (T2*<20 ms, n = 20) compared to those with normal T2*(all p values<0.001). Loge cardiac T2* correlated with SI-QT c (r = -0.609, p<0.001), SD-QTc (r = -0.572, p<0.001), and QTc dispersion (r = -0.622, p<0.001), while all these indices had no relationship with measurements of the left ventricular geometry or function. At the time of study, 10 patients had either heart failure or arrhythmia. All 3 indices of repolarization heterogeneity were related to the presence of adverse cardiac events, with areas under the receiver operating characteristic curves (ranged between 0.79 and 0.86), similar to that of cardiac T2*. Conclusions: Multichannel MCG demonstrated that patients with TM had increased spatial repolarization heterogeneity, which is related to myocardial iron load and adverse cardiac events.
AB - Background: Patients with transfusion-dependent beta-thalassemia major (TM) are at risk for myocardial iron overload and cardiac complications. Spatial repolarization heterogeneity is known to be elevated in patients with certain cardiac diseases, but little is known in TM patients. The purpose of this study was to evaluate spatial repolarization heterogeneity in patients with TM, and to investigate the relationships between spatial repolarization heterogeneity, cardiac iron load, and adverse cardiac events. Methods and Results: Fifty patients with TM and 55 control subjects received 64-channel magnetocardiography (MCG) to determine spatial repolarization heterogeneity, which was evaluated by a smoothness index of QTc (SI-QTc), a standard deviation of QTc (SD-QTc), and a QTc dispersion. Left ventricular function and myocardial T2* values were assessed by cardiac magnetic resonance. Patients with TM had significantly greater SI-QT c, SD-QTc, and QTc dispersion compared to the control subjects (all p values<0.001). Spatial repolarization heterogeneity was even more pronounced in patients with significant iron overload (T2*<20 ms, n = 20) compared to those with normal T2*(all p values<0.001). Loge cardiac T2* correlated with SI-QT c (r = -0.609, p<0.001), SD-QTc (r = -0.572, p<0.001), and QTc dispersion (r = -0.622, p<0.001), while all these indices had no relationship with measurements of the left ventricular geometry or function. At the time of study, 10 patients had either heart failure or arrhythmia. All 3 indices of repolarization heterogeneity were related to the presence of adverse cardiac events, with areas under the receiver operating characteristic curves (ranged between 0.79 and 0.86), similar to that of cardiac T2*. Conclusions: Multichannel MCG demonstrated that patients with TM had increased spatial repolarization heterogeneity, which is related to myocardial iron load and adverse cardiac events.
UR - http://www.scopus.com/inward/record.url?scp=84899956265&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84899956265&partnerID=8YFLogxK
U2 - 10.1371/journal.pone.0086524
DO - 10.1371/journal.pone.0086524
M3 - Article
C2 - 24475137
AN - SCOPUS:84899956265
SN - 1932-6203
VL - 9
JO - PloS one
JF - PloS one
IS - 1
M1 - e86524
ER -