摘要

This study evaluates the feasibility and coefficient of performance of a domestic dehumidifier when its refrigerant is changed from R-134a to R-600a/R-290 mixed refrigerant (50:50 by mass). Without changing any dehumidifier components, experimental results demonstrate that superior performance characteristics can be achieved with 67.5 g of HC refrigerant, which is only 50% of the original mass of the R-134a refrigerant. Generally, the refrigerant in domestic dehumidifiers can be changed from R-134a to a R-600a/R-290 refrigerant mixture, and the ozone depletion potential and global warming potential are negligible when compared with those of the R-134a refrigerant.

原文英語
頁(從 - 到)485-497
頁數13
期刊International Journal of Green Energy
7
發行號5
DOIs
出版狀態已發佈 - 2010 9月