TY - JOUR
T1 - Measurements of natural uranium concentration and isotopic composition with permil-level precision by inductively coupled plasma-quadrupole mass spectrometry
AU - Shen, Chuan Chou
AU - Lin, Huei Ting
AU - Chu, Mei Fei
AU - Yu, Ein Fen
AU - Wang, Xianfeng
AU - Dorale, Jeffrey A.
PY - 2006/9
Y1 - 2006/9
N2 - A new analytical technique using inductively coupled plasma-quadrupole mass spectrometry (ICPQMS) has been developed that produces permil-level precision in the measurement of uranium concentration ([U]) and isotopic composition (δ234U) in natural materials. A 233U-236U double spike method was used to correct for mass fractionation during analysis. To correct for ratio drifting, samples were bracketed by uranium standard measurements. A sensitivity of 6-7 × 108 cps/ppm was generated with a sample solution uptake rate of 30 mL/min. With a measurement time of 15-20 min, standards of 30-ng uranium produced a within-run precision better than 3%(±2 R.S.D.) for δ234U and better than 2%for [U]. Replicate measurements made on standards show that a between-run reproducibility of 3.5%for δ234U and 2% for [U] can be achieved. ICP-QMS data of δ234U and [U] in seawater, coral, and speleothem materials are consistent with the data measured by other ICP-MS and TIMS techniques. Advantages of the ICP-QMS method include low cost, easy maintenance, simple instrumental operation, and few sample preparation steps. Sample size requirements are small, such as 10-14 mg of coral material. The results demonstrate that this technique can be applied to natural samples with various matrices.
AB - A new analytical technique using inductively coupled plasma-quadrupole mass spectrometry (ICPQMS) has been developed that produces permil-level precision in the measurement of uranium concentration ([U]) and isotopic composition (δ234U) in natural materials. A 233U-236U double spike method was used to correct for mass fractionation during analysis. To correct for ratio drifting, samples were bracketed by uranium standard measurements. A sensitivity of 6-7 × 108 cps/ppm was generated with a sample solution uptake rate of 30 mL/min. With a measurement time of 15-20 min, standards of 30-ng uranium produced a within-run precision better than 3%(±2 R.S.D.) for δ234U and better than 2%for [U]. Replicate measurements made on standards show that a between-run reproducibility of 3.5%for δ234U and 2% for [U] can be achieved. ICP-QMS data of δ234U and [U] in seawater, coral, and speleothem materials are consistent with the data measured by other ICP-MS and TIMS techniques. Advantages of the ICP-QMS method include low cost, easy maintenance, simple instrumental operation, and few sample preparation steps. Sample size requirements are small, such as 10-14 mg of coral material. The results demonstrate that this technique can be applied to natural samples with various matrices.
KW - ICP-QMS
KW - Natural uranium
KW - Permil-level precision
KW - δU
UR - http://www.scopus.com/inward/record.url?scp=72049128336&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=72049128336&partnerID=8YFLogxK
U2 - 10.1029/2006GC001303
DO - 10.1029/2006GC001303
M3 - Article
AN - SCOPUS:72049128336
SN - 1525-2027
VL - 7
JO - Geochemistry, Geophysics, Geosystems
JF - Geochemistry, Geophysics, Geosystems
IS - 9
M1 - Q09005
ER -