Biomechanical evaluation of cervical spine fixation after healing in a destabilized cervical spine model in sheep: A comparison of the anterior plating and posterior wiring techniques

Ming Yang Lee, Guan Liang Chang, Jia Hao Chang, Yu Chang Hung, Ching Hong Chang, E. Jian Lee*

*此作品的通信作者

研究成果: 雜誌貢獻期刊論文同行評審

5 引文 斯高帕斯(Scopus)

摘要

BACKGROUND: We conducted biomechanical evaluation of the anterior plating and posterior wiring techniques for cervical spine stabilization after a course of healing in sheep. METHODS: Seventeen sheep were included, and six of which underwent sham operations (group A, n ≤ 6). The other eleven received complete C2-C3 destabilization, followed by intervertebral bone grafting and cervical stabilization either with anterior plating (group B, n ≤ 5) or posterior wiring (group C, n ≤ 6) techniques. These animals were killed 6 months later. Ligamentous spines (C1-C5) were subjected to the relevantly applied loads. The load-deformation data of the C2-C3 and C3-C4 functional units were recorded and analyzed. RESULTS: At the C2-C3 functional unit, group B had the least motion ranges in flexion, lateral bending, and rotation loads than did the other two groups. Significantly smaller motion ranges of lateral bending and rotation loads were found in group B than in group C (p < 0.05). Compared with group A, group C had a decreased motion range in flexion load but showed increased motion range in rotation load. Consequently, group B had superior intervertebral fusion and less osteophyte than did group C. At the C3-C4 functional unit, group B showed significantly decreased motion ranges in extension and lateral bending loads (p < 0.05), while group C did not. CONCLUSION: The results indicated that the anterior plate-stabilized spines were more stable over time than did the posterior-wired spines. This biomechanical advantage eventually resulted in superior intervertebral fusion masses in the former, although it also induced a slightly decreased motion range at the contiguous functional unit. In exclusively posterior wired-spines, the weakness for opposing rotation loads might contribute to the formation of osteophytes at the fusion functional unit. These data point out that the mode and stability of implant fixation systems greatly influence the biomechanical redistribution and bone-adaptive remodeling process during healing, which are closely related to the bone graft maturation and osteophytic formations at the fusion level and the occurrence of stiffening problems at the contiguous levels.

原文英語
頁(從 - 到)1307-1314
頁數8
期刊Journal of Trauma - Injury, Infection and Critical Care
60
發行號6
DOIs
出版狀態已發佈 - 2006 6月
對外發佈

ASJC Scopus subject areas

  • 手術
  • 重症監護和重症監護醫學

指紋

深入研究「Biomechanical evaluation of cervical spine fixation after healing in a destabilized cervical spine model in sheep: A comparison of the anterior plating and posterior wiring techniques」主題。共同形成了獨特的指紋。

引用此