TY - JOUR
T1 - Automatic Detection of Masses From Mammographic Images via Artificial Intelligence Techniques
AU - Azlan, Nur Aainaa Nadirah
AU - Lu, Cheng-Kai
AU - Elamvazuthi, Irraivan
AU - Tang, Tong Boon
PY - 2020
Y1 - 2020
N2 - A novel computer-aided tool for automated sensing of normal tissue and abnormal masses from mammographic X-ray images is described. The pre-processing technique was firstly adopted for noise elimination on mammographic images. The automatic initialization of active contour was then placed on the pre-processed image for segmentation followed by deep convolutional neural networks to extract the features. Principal component analysis was then applied to choose the most significant features as input to the support vector machine classifier. Lastly, k-fold cross-validation techniques were executed for results validation. The developed tool was tested on public available datasets, namely Mammographic Image Analysis Society, and Digital Database for Screening Mammogram, based on eight evaluation methods: accuracy, sensitivity, specificity, receiver operating characteristic curve, area under curve (AUC), F1-score, precision, and recall. The outcome demonstrated the proposed system as a competitive tool in assisting radiologists as it attains an average of 95.24%, 93.94%, 96.61%, 94.66, 93.00%, 94.34%, and 0.98 for accuracy, sensitivity, specificity, precision, recall, F1-score, and AUC, respectively for testing on a combination of the aforementioned two datasets.
AB - A novel computer-aided tool for automated sensing of normal tissue and abnormal masses from mammographic X-ray images is described. The pre-processing technique was firstly adopted for noise elimination on mammographic images. The automatic initialization of active contour was then placed on the pre-processed image for segmentation followed by deep convolutional neural networks to extract the features. Principal component analysis was then applied to choose the most significant features as input to the support vector machine classifier. Lastly, k-fold cross-validation techniques were executed for results validation. The developed tool was tested on public available datasets, namely Mammographic Image Analysis Society, and Digital Database for Screening Mammogram, based on eight evaluation methods: accuracy, sensitivity, specificity, receiver operating characteristic curve, area under curve (AUC), F1-score, precision, and recall. The outcome demonstrated the proposed system as a competitive tool in assisting radiologists as it attains an average of 95.24%, 93.94%, 96.61%, 94.66, 93.00%, 94.34%, and 0.98 for accuracy, sensitivity, specificity, precision, recall, F1-score, and AUC, respectively for testing on a combination of the aforementioned two datasets.
UR - https://www.scopus.com/pages/publications/85092502788
UR - https://www.scopus.com/pages/publications/85092502788#tab=citedBy
U2 - 10.1109/JSEN.2020.3002559
DO - 10.1109/JSEN.2020.3002559
M3 - Article
AN - SCOPUS:85092502788
SN - 1530-437X
JO - IEEE Sensors Journal
JF - IEEE Sensors Journal
ER -