An integrated multi parameters wearable telemetric system for cardio-pulmonary signal measurement

Tsung Che Chou, Nan Fu Chiu, Feng Ping, Shey Shi Lu, Chang Rung Yang, Szu Yuan Lee, Chii Wann Lin

    研究成果: 雜誌貢獻文章

    摘要

    We report a multi parameters cardiopulmonary (CP) monitoring system with features of low power consumptions (40 mA,3.7V), miniaturization (size 6×5 cm2), and multi wireless data communication channels (Frequency 315,432,916 MHz) for wearable applications in e-Health. Its target application is for the evaluation health of CP on Homecare, Patient Isolation and quarantine, Recreational sports market. We use a miniature bi-directional hot-wire sensor for respiratory function, an optical sensor for s plethsymograph, and two surface electrodes for single lead electrocardiograph. The parameters include Pulse, ECG, and respiratory functions, which will be used for the quantitative evaluation of heart rate, pulse rate and respiratory rate.

    原文英語
    頁(從 - 到)469-473
    頁數5
    期刊IFMBE Proceedings
    14
    發行號1
    出版狀態已發佈 - 2007

    指紋

    Health
    Optical sensors
    Sports
    Electrocardiography
    Electric power utilization
    Lead
    Wire
    Electrodes
    Monitoring
    Sensors

    ASJC Scopus subject areas

    • Bioengineering
    • Biomedical Engineering

    引用此文

    Chou, T. C., Chiu, N. F., Ping, F., Lu, S. S., Yang, C. R., Lee, S. Y., & Lin, C. W. (2007). An integrated multi parameters wearable telemetric system for cardio-pulmonary signal measurement. IFMBE Proceedings, 14(1), 469-473.

    An integrated multi parameters wearable telemetric system for cardio-pulmonary signal measurement. / Chou, Tsung Che; Chiu, Nan Fu; Ping, Feng; Lu, Shey Shi; Yang, Chang Rung; Lee, Szu Yuan; Lin, Chii Wann.

    於: IFMBE Proceedings, 卷 14, 編號 1, 2007, p. 469-473.

    研究成果: 雜誌貢獻文章

    Chou, TC, Chiu, NF, Ping, F, Lu, SS, Yang, CR, Lee, SY & Lin, CW 2007, 'An integrated multi parameters wearable telemetric system for cardio-pulmonary signal measurement', IFMBE Proceedings, 卷 14, 編號 1, 頁 469-473.
    Chou, Tsung Che ; Chiu, Nan Fu ; Ping, Feng ; Lu, Shey Shi ; Yang, Chang Rung ; Lee, Szu Yuan ; Lin, Chii Wann. / An integrated multi parameters wearable telemetric system for cardio-pulmonary signal measurement. 於: IFMBE Proceedings. 2007 ; 卷 14, 編號 1. 頁 469-473.
    @article{7eafc0a67f5e42a9ac0605d322361a12,
    title = "An integrated multi parameters wearable telemetric system for cardio-pulmonary signal measurement",
    abstract = "We report a multi parameters cardiopulmonary (CP) monitoring system with features of low power consumptions (40 mA,3.7V), miniaturization (size 6×5 cm2), and multi wireless data communication channels (Frequency 315,432,916 MHz) for wearable applications in e-Health. Its target application is for the evaluation health of CP on Homecare, Patient Isolation and quarantine, Recreational sports market. We use a miniature bi-directional hot-wire sensor for respiratory function, an optical sensor for s plethsymograph, and two surface electrodes for single lead electrocardiograph. The parameters include Pulse, ECG, and respiratory functions, which will be used for the quantitative evaluation of heart rate, pulse rate and respiratory rate.",
    keywords = "Cardio-pulmonary signal measurement, E-Health, MEMS, Multi parameters, Wearable monitoring system",
    author = "Chou, {Tsung Che} and Chiu, {Nan Fu} and Feng Ping and Lu, {Shey Shi} and Yang, {Chang Rung} and Lee, {Szu Yuan} and Lin, {Chii Wann}",
    year = "2007",
    language = "English",
    volume = "14",
    pages = "469--473",
    journal = "IFMBE Proceedings",
    issn = "1680-0737",
    publisher = "Springer Verlag",
    number = "1",

    }

    TY - JOUR

    T1 - An integrated multi parameters wearable telemetric system for cardio-pulmonary signal measurement

    AU - Chou, Tsung Che

    AU - Chiu, Nan Fu

    AU - Ping, Feng

    AU - Lu, Shey Shi

    AU - Yang, Chang Rung

    AU - Lee, Szu Yuan

    AU - Lin, Chii Wann

    PY - 2007

    Y1 - 2007

    N2 - We report a multi parameters cardiopulmonary (CP) monitoring system with features of low power consumptions (40 mA,3.7V), miniaturization (size 6×5 cm2), and multi wireless data communication channels (Frequency 315,432,916 MHz) for wearable applications in e-Health. Its target application is for the evaluation health of CP on Homecare, Patient Isolation and quarantine, Recreational sports market. We use a miniature bi-directional hot-wire sensor for respiratory function, an optical sensor for s plethsymograph, and two surface electrodes for single lead electrocardiograph. The parameters include Pulse, ECG, and respiratory functions, which will be used for the quantitative evaluation of heart rate, pulse rate and respiratory rate.

    AB - We report a multi parameters cardiopulmonary (CP) monitoring system with features of low power consumptions (40 mA,3.7V), miniaturization (size 6×5 cm2), and multi wireless data communication channels (Frequency 315,432,916 MHz) for wearable applications in e-Health. Its target application is for the evaluation health of CP on Homecare, Patient Isolation and quarantine, Recreational sports market. We use a miniature bi-directional hot-wire sensor for respiratory function, an optical sensor for s plethsymograph, and two surface electrodes for single lead electrocardiograph. The parameters include Pulse, ECG, and respiratory functions, which will be used for the quantitative evaluation of heart rate, pulse rate and respiratory rate.

    KW - Cardio-pulmonary signal measurement

    KW - E-Health

    KW - MEMS

    KW - Multi parameters

    KW - Wearable monitoring system

    UR - http://www.scopus.com/inward/record.url?scp=84958250772&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=84958250772&partnerID=8YFLogxK

    M3 - Article

    AN - SCOPUS:84958250772

    VL - 14

    SP - 469

    EP - 473

    JO - IFMBE Proceedings

    JF - IFMBE Proceedings

    SN - 1680-0737

    IS - 1

    ER -