Whole body screening using high-temperature superconducting MR volume resonators: Mice studies

In Tsang Lin, Hong Chang Yang, Jyh Horng Chen

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

High temperature superconducting (HTS) surface resonators have been used as a low loss RF receiver resonator for improving magnetic resonance imaging image quality. However, the application of HTS surface resonators is significantly limited by their filling factor. To maximize the filling factor, it is desirable to have the RF resonator wrapped around the sample so that more nuclear magnetic dipoles can contribute to the signal. In this study, a whole new Bi 2Sr 2Ca 2Cu 2O 3 (Bi-2223) superconducting saddle resonator (width of 5 cm and length of 8 cm) was designed for the magnetic resonance image of a mouse's whole body in Bruker 3 T MRI system. The experiment was conducted with a professionally-made copper saddle resonator and a Bi-2223 saddle resonator to show the difference. Signal-to-noise ratio (SNR) with the HTS saddle resonator at 77 K was 2.1 and 2 folds higher than that of the copper saddle resonator at 300 K for a phantom and an in-vivo mice whole body imaging. Testing results were in accordance with predicted ones, and the difference between the predicted SNR gains and measured SNR gains were 2.4%~2.7%. In summary, with this HTS saddle system, a mouse's whole body can be imaged in one scan and could reach a high SNR due to a 2 folds SNR gain over the professionally-made prototype of copper saddle resonator at 300 K. The use of HTS saddle resonator not only improves SNR but also enables a mouse's whole body screen in one scan.

Original languageEnglish
Article numbere33207
JournalPloS one
Volume7
Issue number4
DOIs
Publication statusPublished - 2012 Apr 6

Fingerprint

Whole Body Imaging
saddles
Signal-To-Noise Ratio
Resonators
Screening
screening
Signal to noise ratio
Temperature
Superconducting resonators
mice
Copper
temperature
copper
Magnetic resonance
Imaging techniques
Magnetic Resonance Spectroscopy
magnetic resonance imaging
Magnetic Resonance Imaging
prototypes
Magnetic resonance imaging

ASJC Scopus subject areas

  • Biochemistry, Genetics and Molecular Biology(all)
  • Agricultural and Biological Sciences(all)

Cite this

Whole body screening using high-temperature superconducting MR volume resonators : Mice studies. / Lin, In Tsang; Yang, Hong Chang; Chen, Jyh Horng.

In: PloS one, Vol. 7, No. 4, e33207, 06.04.2012.

Research output: Contribution to journalArticle

Lin, In Tsang ; Yang, Hong Chang ; Chen, Jyh Horng. / Whole body screening using high-temperature superconducting MR volume resonators : Mice studies. In: PloS one. 2012 ; Vol. 7, No. 4.
@article{85086d127c8b49318dc1613524640526,
title = "Whole body screening using high-temperature superconducting MR volume resonators: Mice studies",
abstract = "High temperature superconducting (HTS) surface resonators have been used as a low loss RF receiver resonator for improving magnetic resonance imaging image quality. However, the application of HTS surface resonators is significantly limited by their filling factor. To maximize the filling factor, it is desirable to have the RF resonator wrapped around the sample so that more nuclear magnetic dipoles can contribute to the signal. In this study, a whole new Bi 2Sr 2Ca 2Cu 2O 3 (Bi-2223) superconducting saddle resonator (width of 5 cm and length of 8 cm) was designed for the magnetic resonance image of a mouse's whole body in Bruker 3 T MRI system. The experiment was conducted with a professionally-made copper saddle resonator and a Bi-2223 saddle resonator to show the difference. Signal-to-noise ratio (SNR) with the HTS saddle resonator at 77 K was 2.1 and 2 folds higher than that of the copper saddle resonator at 300 K for a phantom and an in-vivo mice whole body imaging. Testing results were in accordance with predicted ones, and the difference between the predicted SNR gains and measured SNR gains were 2.4{\%}~2.7{\%}. In summary, with this HTS saddle system, a mouse's whole body can be imaged in one scan and could reach a high SNR due to a 2 folds SNR gain over the professionally-made prototype of copper saddle resonator at 300 K. The use of HTS saddle resonator not only improves SNR but also enables a mouse's whole body screen in one scan.",
author = "Lin, {In Tsang} and Yang, {Hong Chang} and Chen, {Jyh Horng}",
year = "2012",
month = "4",
day = "6",
doi = "10.1371/journal.pone.0033207",
language = "English",
volume = "7",
journal = "PLoS One",
issn = "1932-6203",
publisher = "Public Library of Science",
number = "4",

}

TY - JOUR

T1 - Whole body screening using high-temperature superconducting MR volume resonators

T2 - Mice studies

AU - Lin, In Tsang

AU - Yang, Hong Chang

AU - Chen, Jyh Horng

PY - 2012/4/6

Y1 - 2012/4/6

N2 - High temperature superconducting (HTS) surface resonators have been used as a low loss RF receiver resonator for improving magnetic resonance imaging image quality. However, the application of HTS surface resonators is significantly limited by their filling factor. To maximize the filling factor, it is desirable to have the RF resonator wrapped around the sample so that more nuclear magnetic dipoles can contribute to the signal. In this study, a whole new Bi 2Sr 2Ca 2Cu 2O 3 (Bi-2223) superconducting saddle resonator (width of 5 cm and length of 8 cm) was designed for the magnetic resonance image of a mouse's whole body in Bruker 3 T MRI system. The experiment was conducted with a professionally-made copper saddle resonator and a Bi-2223 saddle resonator to show the difference. Signal-to-noise ratio (SNR) with the HTS saddle resonator at 77 K was 2.1 and 2 folds higher than that of the copper saddle resonator at 300 K for a phantom and an in-vivo mice whole body imaging. Testing results were in accordance with predicted ones, and the difference between the predicted SNR gains and measured SNR gains were 2.4%~2.7%. In summary, with this HTS saddle system, a mouse's whole body can be imaged in one scan and could reach a high SNR due to a 2 folds SNR gain over the professionally-made prototype of copper saddle resonator at 300 K. The use of HTS saddle resonator not only improves SNR but also enables a mouse's whole body screen in one scan.

AB - High temperature superconducting (HTS) surface resonators have been used as a low loss RF receiver resonator for improving magnetic resonance imaging image quality. However, the application of HTS surface resonators is significantly limited by their filling factor. To maximize the filling factor, it is desirable to have the RF resonator wrapped around the sample so that more nuclear magnetic dipoles can contribute to the signal. In this study, a whole new Bi 2Sr 2Ca 2Cu 2O 3 (Bi-2223) superconducting saddle resonator (width of 5 cm and length of 8 cm) was designed for the magnetic resonance image of a mouse's whole body in Bruker 3 T MRI system. The experiment was conducted with a professionally-made copper saddle resonator and a Bi-2223 saddle resonator to show the difference. Signal-to-noise ratio (SNR) with the HTS saddle resonator at 77 K was 2.1 and 2 folds higher than that of the copper saddle resonator at 300 K for a phantom and an in-vivo mice whole body imaging. Testing results were in accordance with predicted ones, and the difference between the predicted SNR gains and measured SNR gains were 2.4%~2.7%. In summary, with this HTS saddle system, a mouse's whole body can be imaged in one scan and could reach a high SNR due to a 2 folds SNR gain over the professionally-made prototype of copper saddle resonator at 300 K. The use of HTS saddle resonator not only improves SNR but also enables a mouse's whole body screen in one scan.

UR - http://www.scopus.com/inward/record.url?scp=84859478948&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84859478948&partnerID=8YFLogxK

U2 - 10.1371/journal.pone.0033207

DO - 10.1371/journal.pone.0033207

M3 - Article

C2 - 22493666

AN - SCOPUS:84859478948

VL - 7

JO - PLoS One

JF - PLoS One

SN - 1932-6203

IS - 4

M1 - e33207

ER -