The characteristics of the initial three synchrotron radiation beam lines at SRRC

Chu Nan Chang, Ching Iue Chen, Yen Fang Song, Ping Chung Tseng, Liang Ren Huang

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

The design of three beam lines has been finished at Synchrotron Radiation Research Center (SRRC), Taiwan, by the SRRC staff. The 1-m Seya-Namioko monochromator (SNM). 6-m spherical grating monochromator (SGM), and 6-m cylindrical-element monochromator are used for these beam lines. A brief description of the concept behind the design of each beam line will be made. The choice of the demagnification of the vertical focus mirror for both SGM and CEM beam lines was found important for low-emittance machines. The degradation of beam quality due to imperfections in the mirror surface was found crucial for prefocus mirrors.

Original languageEnglish
Pages (from-to)152-156
Number of pages5
JournalNuclear Inst. and Methods in Physics Research, A
Volume291
Issue number1-2
DOIs
Publication statusPublished - 1990 May 20

Fingerprint

Monochromators
Synchrotron radiation
synchrotron radiation
monochromators
mirrors
Mirrors
Beam quality
gratings
Taiwan
emittance
Degradation
Defects
degradation
defects

ASJC Scopus subject areas

  • Nuclear and High Energy Physics
  • Instrumentation

Cite this

The characteristics of the initial three synchrotron radiation beam lines at SRRC. / Chang, Chu Nan; Chen, Ching Iue; Song, Yen Fang; Tseng, Ping Chung; Huang, Liang Ren.

In: Nuclear Inst. and Methods in Physics Research, A, Vol. 291, No. 1-2, 20.05.1990, p. 152-156.

Research output: Contribution to journalArticle

Chang, Chu Nan ; Chen, Ching Iue ; Song, Yen Fang ; Tseng, Ping Chung ; Huang, Liang Ren. / The characteristics of the initial three synchrotron radiation beam lines at SRRC. In: Nuclear Inst. and Methods in Physics Research, A. 1990 ; Vol. 291, No. 1-2. pp. 152-156.
@article{1a69203e75364ffca662bc15545391d2,
title = "The characteristics of the initial three synchrotron radiation beam lines at SRRC",
abstract = "The design of three beam lines has been finished at Synchrotron Radiation Research Center (SRRC), Taiwan, by the SRRC staff. The 1-m Seya-Namioko monochromator (SNM). 6-m spherical grating monochromator (SGM), and 6-m cylindrical-element monochromator are used for these beam lines. A brief description of the concept behind the design of each beam line will be made. The choice of the demagnification of the vertical focus mirror for both SGM and CEM beam lines was found important for low-emittance machines. The degradation of beam quality due to imperfections in the mirror surface was found crucial for prefocus mirrors.",
author = "Chang, {Chu Nan} and Chen, {Ching Iue} and Song, {Yen Fang} and Tseng, {Ping Chung} and Huang, {Liang Ren}",
year = "1990",
month = "5",
day = "20",
doi = "10.1016/0168-9002(90)90051-7",
language = "English",
volume = "291",
pages = "152--156",
journal = "Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment",
issn = "0168-9002",
publisher = "Elsevier",
number = "1-2",

}

TY - JOUR

T1 - The characteristics of the initial three synchrotron radiation beam lines at SRRC

AU - Chang, Chu Nan

AU - Chen, Ching Iue

AU - Song, Yen Fang

AU - Tseng, Ping Chung

AU - Huang, Liang Ren

PY - 1990/5/20

Y1 - 1990/5/20

N2 - The design of three beam lines has been finished at Synchrotron Radiation Research Center (SRRC), Taiwan, by the SRRC staff. The 1-m Seya-Namioko monochromator (SNM). 6-m spherical grating monochromator (SGM), and 6-m cylindrical-element monochromator are used for these beam lines. A brief description of the concept behind the design of each beam line will be made. The choice of the demagnification of the vertical focus mirror for both SGM and CEM beam lines was found important for low-emittance machines. The degradation of beam quality due to imperfections in the mirror surface was found crucial for prefocus mirrors.

AB - The design of three beam lines has been finished at Synchrotron Radiation Research Center (SRRC), Taiwan, by the SRRC staff. The 1-m Seya-Namioko monochromator (SNM). 6-m spherical grating monochromator (SGM), and 6-m cylindrical-element monochromator are used for these beam lines. A brief description of the concept behind the design of each beam line will be made. The choice of the demagnification of the vertical focus mirror for both SGM and CEM beam lines was found important for low-emittance machines. The degradation of beam quality due to imperfections in the mirror surface was found crucial for prefocus mirrors.

UR - http://www.scopus.com/inward/record.url?scp=44949269978&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=44949269978&partnerID=8YFLogxK

U2 - 10.1016/0168-9002(90)90051-7

DO - 10.1016/0168-9002(90)90051-7

M3 - Article

AN - SCOPUS:44949269978

VL - 291

SP - 152

EP - 156

JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

SN - 0168-9002

IS - 1-2

ER -