The balance and noise properties of directly coupled high-Tc superconducting quantum interference device gradiometers with a serial array

Hong Chang Yang, J. C. Chen, C. H. Wu, K. L. Chen, Herng Er Horng, Yi Shou Tsai, S. Y. Yang

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

We characterize the balance and noise properties of directly coupled high- Tc superconducting quantum interference device (SQUID) gradiometers with a series array. The gradiometer consisted of symmetrical pickup loops, in which a series of SQUID was symmetrically configured and directly coupled to pickup loops. We characterize the balance resolution B from the following formula: B= Aeff,uniform field Aeff,gradient field, where Aeff,uniform field and Aeff,gradient field are the parasitic effective area and the effective area of the gradiometer, respectively. We obtained B=1.25× 10-2 which was comparable to the typical balance resolution of ∼ 10-2 for a gradiometer fabricated onto the 10×10 mm2 substrate. This discrepancy was probably due to the many superconducting pads inside the pickup loops which deteriorated the uniformity of applied uniform magnetic fields. The gradient field sensitivity of ∼40 fT Hz12 cm at 1 kHz for two-SQUID gradiometers was demonstrated in a magnetically unshielded environment, which was comparable to the best gradient sensitivity of 30 fT Hz12 cm, with gradiometric flip-chip flux transformer with a length of 24 mm and a base line of 10 mm in shielded environment.

Original languageEnglish
Article number033501
JournalApplied Physics Letters
Volume92
Issue number3
DOIs
Publication statusPublished - 2008 Feb 1

Fingerprint

gradiometers
interference
gradients
sensors
transformers
chips
sensitivity
magnetic fields

ASJC Scopus subject areas

  • Physics and Astronomy (miscellaneous)

Cite this

The balance and noise properties of directly coupled high-Tc superconducting quantum interference device gradiometers with a serial array. / Yang, Hong Chang; Chen, J. C.; Wu, C. H.; Chen, K. L.; Horng, Herng Er; Tsai, Yi Shou; Yang, S. Y.

In: Applied Physics Letters, Vol. 92, No. 3, 033501, 01.02.2008.

Research output: Contribution to journalArticle

Yang, Hong Chang ; Chen, J. C. ; Wu, C. H. ; Chen, K. L. ; Horng, Herng Er ; Tsai, Yi Shou ; Yang, S. Y. / The balance and noise properties of directly coupled high-Tc superconducting quantum interference device gradiometers with a serial array. In: Applied Physics Letters. 2008 ; Vol. 92, No. 3.
@article{2cea54faee934f06988353b5d7728232,
title = "The balance and noise properties of directly coupled high-Tc superconducting quantum interference device gradiometers with a serial array",
abstract = "We characterize the balance and noise properties of directly coupled high- Tc superconducting quantum interference device (SQUID) gradiometers with a series array. The gradiometer consisted of symmetrical pickup loops, in which a series of SQUID was symmetrically configured and directly coupled to pickup loops. We characterize the balance resolution B from the following formula: B= Aeff,uniform field Aeff,gradient field, where Aeff,uniform field and Aeff,gradient field are the parasitic effective area and the effective area of the gradiometer, respectively. We obtained B=1.25× 10-2 which was comparable to the typical balance resolution of ∼ 10-2 for a gradiometer fabricated onto the 10×10 mm2 substrate. This discrepancy was probably due to the many superconducting pads inside the pickup loops which deteriorated the uniformity of applied uniform magnetic fields. The gradient field sensitivity of ∼40 fT Hz12 cm at 1 kHz for two-SQUID gradiometers was demonstrated in a magnetically unshielded environment, which was comparable to the best gradient sensitivity of 30 fT Hz12 cm, with gradiometric flip-chip flux transformer with a length of 24 mm and a base line of 10 mm in shielded environment.",
author = "Yang, {Hong Chang} and Chen, {J. C.} and Wu, {C. H.} and Chen, {K. L.} and Horng, {Herng Er} and Tsai, {Yi Shou} and Yang, {S. Y.}",
year = "2008",
month = "2",
day = "1",
doi = "10.1063/1.2835700",
language = "English",
volume = "92",
journal = "Applied Physics Letters",
issn = "0003-6951",
publisher = "American Institute of Physics Publising LLC",
number = "3",

}

TY - JOUR

T1 - The balance and noise properties of directly coupled high-Tc superconducting quantum interference device gradiometers with a serial array

AU - Yang, Hong Chang

AU - Chen, J. C.

AU - Wu, C. H.

AU - Chen, K. L.

AU - Horng, Herng Er

AU - Tsai, Yi Shou

AU - Yang, S. Y.

PY - 2008/2/1

Y1 - 2008/2/1

N2 - We characterize the balance and noise properties of directly coupled high- Tc superconducting quantum interference device (SQUID) gradiometers with a series array. The gradiometer consisted of symmetrical pickup loops, in which a series of SQUID was symmetrically configured and directly coupled to pickup loops. We characterize the balance resolution B from the following formula: B= Aeff,uniform field Aeff,gradient field, where Aeff,uniform field and Aeff,gradient field are the parasitic effective area and the effective area of the gradiometer, respectively. We obtained B=1.25× 10-2 which was comparable to the typical balance resolution of ∼ 10-2 for a gradiometer fabricated onto the 10×10 mm2 substrate. This discrepancy was probably due to the many superconducting pads inside the pickup loops which deteriorated the uniformity of applied uniform magnetic fields. The gradient field sensitivity of ∼40 fT Hz12 cm at 1 kHz for two-SQUID gradiometers was demonstrated in a magnetically unshielded environment, which was comparable to the best gradient sensitivity of 30 fT Hz12 cm, with gradiometric flip-chip flux transformer with a length of 24 mm and a base line of 10 mm in shielded environment.

AB - We characterize the balance and noise properties of directly coupled high- Tc superconducting quantum interference device (SQUID) gradiometers with a series array. The gradiometer consisted of symmetrical pickup loops, in which a series of SQUID was symmetrically configured and directly coupled to pickup loops. We characterize the balance resolution B from the following formula: B= Aeff,uniform field Aeff,gradient field, where Aeff,uniform field and Aeff,gradient field are the parasitic effective area and the effective area of the gradiometer, respectively. We obtained B=1.25× 10-2 which was comparable to the typical balance resolution of ∼ 10-2 for a gradiometer fabricated onto the 10×10 mm2 substrate. This discrepancy was probably due to the many superconducting pads inside the pickup loops which deteriorated the uniformity of applied uniform magnetic fields. The gradient field sensitivity of ∼40 fT Hz12 cm at 1 kHz for two-SQUID gradiometers was demonstrated in a magnetically unshielded environment, which was comparable to the best gradient sensitivity of 30 fT Hz12 cm, with gradiometric flip-chip flux transformer with a length of 24 mm and a base line of 10 mm in shielded environment.

UR - http://www.scopus.com/inward/record.url?scp=38549147930&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=38549147930&partnerID=8YFLogxK

U2 - 10.1063/1.2835700

DO - 10.1063/1.2835700

M3 - Article

AN - SCOPUS:38549147930

VL - 92

JO - Applied Physics Letters

JF - Applied Physics Letters

SN - 0003-6951

IS - 3

M1 - 033501

ER -