Study on positioning accuracy of reciprocating friction drive system

Chii-Rong Yang, Yuang Cherng Chiou, Rong Tsong Lee

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

The positioning accuracy of the friction drive system was analyzed experimentally and theoretically in the reciprocating friction drive tester under the dry contact using the specimen of medium carbon steel S45C. Effects of normal load, driver speed and spring constant on the positioning accuracy are investigated in this study. Results show that the traction force calculated from the kinematic analysis under pure rolling assumption agrees well with the experimental values. Based on the experimental results, the correlation formula of slip displacement in terms of the amplitude of traction force, driver speed and normal load is obtained for a wide range of operating parameters. To obtain a better positioning accuracy, the amplitude of traction force should be close to zero for both zones, S < 0 and S > 0. At very low spring constant, higher normal load has a better positioning accuracy than lower normal load. However, at high spring constant, since the tangential force generated from the spring and higher normal load on the contact surface would produce severe wear or peaks at two limit positions, lower normal load has better positioning accuracy than higher normal load.

Original languageEnglish
Pages (from-to)58-65
Number of pages8
JournalWear
Volume189
Issue number1-2
DOIs
Publication statusPublished - 1995 Jan 1

Fingerprint

positioning
friction
Friction
traction
Carbon steel
Kinematics
Wear of materials
carbon steels
test equipment
slip
kinematics

Keywords

  • Friction drive system
  • Positioning accuracy
  • Severe wear

ASJC Scopus subject areas

  • Condensed Matter Physics
  • Mechanics of Materials
  • Surfaces and Interfaces
  • Surfaces, Coatings and Films
  • Materials Chemistry

Cite this

Study on positioning accuracy of reciprocating friction drive system. / Yang, Chii-Rong; Chiou, Yuang Cherng; Lee, Rong Tsong.

In: Wear, Vol. 189, No. 1-2, 01.01.1995, p. 58-65.

Research output: Contribution to journalArticle

Yang, Chii-Rong ; Chiou, Yuang Cherng ; Lee, Rong Tsong. / Study on positioning accuracy of reciprocating friction drive system. In: Wear. 1995 ; Vol. 189, No. 1-2. pp. 58-65.
@article{f6febb0b9af74871b270361be2206ba9,
title = "Study on positioning accuracy of reciprocating friction drive system",
abstract = "The positioning accuracy of the friction drive system was analyzed experimentally and theoretically in the reciprocating friction drive tester under the dry contact using the specimen of medium carbon steel S45C. Effects of normal load, driver speed and spring constant on the positioning accuracy are investigated in this study. Results show that the traction force calculated from the kinematic analysis under pure rolling assumption agrees well with the experimental values. Based on the experimental results, the correlation formula of slip displacement in terms of the amplitude of traction force, driver speed and normal load is obtained for a wide range of operating parameters. To obtain a better positioning accuracy, the amplitude of traction force should be close to zero for both zones, S < 0 and S > 0. At very low spring constant, higher normal load has a better positioning accuracy than lower normal load. However, at high spring constant, since the tangential force generated from the spring and higher normal load on the contact surface would produce severe wear or peaks at two limit positions, lower normal load has better positioning accuracy than higher normal load.",
keywords = "Friction drive system, Positioning accuracy, Severe wear",
author = "Chii-Rong Yang and Chiou, {Yuang Cherng} and Lee, {Rong Tsong}",
year = "1995",
month = "1",
day = "1",
doi = "10.1016/0043-1648(95)06640-3",
language = "English",
volume = "189",
pages = "58--65",
journal = "Wear",
issn = "0043-1648",
publisher = "Elsevier BV",
number = "1-2",

}

TY - JOUR

T1 - Study on positioning accuracy of reciprocating friction drive system

AU - Yang, Chii-Rong

AU - Chiou, Yuang Cherng

AU - Lee, Rong Tsong

PY - 1995/1/1

Y1 - 1995/1/1

N2 - The positioning accuracy of the friction drive system was analyzed experimentally and theoretically in the reciprocating friction drive tester under the dry contact using the specimen of medium carbon steel S45C. Effects of normal load, driver speed and spring constant on the positioning accuracy are investigated in this study. Results show that the traction force calculated from the kinematic analysis under pure rolling assumption agrees well with the experimental values. Based on the experimental results, the correlation formula of slip displacement in terms of the amplitude of traction force, driver speed and normal load is obtained for a wide range of operating parameters. To obtain a better positioning accuracy, the amplitude of traction force should be close to zero for both zones, S < 0 and S > 0. At very low spring constant, higher normal load has a better positioning accuracy than lower normal load. However, at high spring constant, since the tangential force generated from the spring and higher normal load on the contact surface would produce severe wear or peaks at two limit positions, lower normal load has better positioning accuracy than higher normal load.

AB - The positioning accuracy of the friction drive system was analyzed experimentally and theoretically in the reciprocating friction drive tester under the dry contact using the specimen of medium carbon steel S45C. Effects of normal load, driver speed and spring constant on the positioning accuracy are investigated in this study. Results show that the traction force calculated from the kinematic analysis under pure rolling assumption agrees well with the experimental values. Based on the experimental results, the correlation formula of slip displacement in terms of the amplitude of traction force, driver speed and normal load is obtained for a wide range of operating parameters. To obtain a better positioning accuracy, the amplitude of traction force should be close to zero for both zones, S < 0 and S > 0. At very low spring constant, higher normal load has a better positioning accuracy than lower normal load. However, at high spring constant, since the tangential force generated from the spring and higher normal load on the contact surface would produce severe wear or peaks at two limit positions, lower normal load has better positioning accuracy than higher normal load.

KW - Friction drive system

KW - Positioning accuracy

KW - Severe wear

UR - http://www.scopus.com/inward/record.url?scp=0029387368&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0029387368&partnerID=8YFLogxK

U2 - 10.1016/0043-1648(95)06640-3

DO - 10.1016/0043-1648(95)06640-3

M3 - Article

AN - SCOPUS:0029387368

VL - 189

SP - 58

EP - 65

JO - Wear

JF - Wear

SN - 0043-1648

IS - 1-2

ER -