TY - JOUR
T1 - Sampling and profiling caffeine and its metabolites from an eyelid using a watercolor pen based on electrospray ionization/mass spectrometry
AU - Liou, Yea Wenn
AU - Chang, Kai Yin
AU - Lin, Cheng Huang
N1 - Publisher Copyright:
© 2017 Elsevier B.V.
PY - 2017/11
Y1 - 2017/11
N2 - A novel and non-invasive sampling method was developed for use in electrospray ionization/mass spectrometry (ESI/MS). The sampling tool, a watercolor pen (brush) that had been rinsed with ethanol, was used to collect analytes from the eyelids of volunteers. Following this, the brush was quickly moved to the front of the mass inlet, where the ethanol as well as the analytes evaporated very fast and escaped from the brush surface. When the analytes make contact with the ESI plume, which arises from the ESI needle tip, they are ionized and then detected by a mass spectrometer. The findings show that this new technique is applicable for the analysis of caffeine and its metabolites in samples obtained from eyelids after the volunteers consumed coffee. The methodology is simple and economical, non-invasive, and is suitable for use in monitoring the levels of caffeine and its metabolites over an extended period of time.
AB - A novel and non-invasive sampling method was developed for use in electrospray ionization/mass spectrometry (ESI/MS). The sampling tool, a watercolor pen (brush) that had been rinsed with ethanol, was used to collect analytes from the eyelids of volunteers. Following this, the brush was quickly moved to the front of the mass inlet, where the ethanol as well as the analytes evaporated very fast and escaped from the brush surface. When the analytes make contact with the ESI plume, which arises from the ESI needle tip, they are ionized and then detected by a mass spectrometer. The findings show that this new technique is applicable for the analysis of caffeine and its metabolites in samples obtained from eyelids after the volunteers consumed coffee. The methodology is simple and economical, non-invasive, and is suitable for use in monitoring the levels of caffeine and its metabolites over an extended period of time.
KW - Caffeine
KW - ESI/mass spectrometry
KW - Metabolite
KW - Non-invasive sampling
KW - Watercolor pen
UR - http://www.scopus.com/inward/record.url?scp=85029795016&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85029795016&partnerID=8YFLogxK
U2 - 10.1016/j.ijms.2017.08.010
DO - 10.1016/j.ijms.2017.08.010
M3 - Article
AN - SCOPUS:85029795016
SN - 1387-3806
VL - 422
SP - 51
EP - 55
JO - International Journal of Mass Spectrometry
JF - International Journal of Mass Spectrometry
ER -