Optimization of the detection coil of high-Tc superconducting quantum interference device-based nuclear magnetic resonance for discriminating a minimum amount of liver tumor of rats in microtesla fields

Hsin Hsien Chen, Kai Wen Huang, Hong-Chang Yang, Herng-Er Horng, Shu-Hsien Liao

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

This study presents an optimization of the detection coil of high-T c superconducting quantum interference device (SQUID)-based nuclear magnetic resonance (NMR) in microtesla fields for discriminating a minimum amount of liver tumor in rats by characterizing the longitudinal relaxation rate, T1-1, of tested samples. The detection coil, which was coupled to the SQUID through a flux transformer, was optimized by varying the copper wires' winding turns and diameters. When comparing the measured NMR signals, we found that the simulated NMR signal agrees with simulated signals. When discriminating liver tumors in rats, the averaged longitudinal relaxation rate was observed to be T1-1 = 3.3 s-1 for cancerous liver tissue and T1-1 = 6.6 s-1 for normal liver tissue. The results suggest that it can be used to successfully discriminate cancerous liver tissue from normal liver tissues in rats. The minimum amount of samples that can be detected is 0.2 g for liver tumor and 0.4 g for normal liver tissue in 100 μT fields. The specimen was not damaged; it can be used for other pathological analyses. The proposed method provides more possibilities for examining undersized specimens.

Original languageEnglish
Article number064701
JournalJournal of Applied Physics
Volume114
Issue number6
DOIs
Publication statusPublished - 2013 Aug 14

Fingerprint

liver
rats
coils
tumors
interference
nuclear magnetic resonance
optimization
wire winding
transformers
copper

ASJC Scopus subject areas

  • Physics and Astronomy(all)

Cite this

@article{e54657a50ab14b29982adc81861df24b,
title = "Optimization of the detection coil of high-Tc superconducting quantum interference device-based nuclear magnetic resonance for discriminating a minimum amount of liver tumor of rats in microtesla fields",
abstract = "This study presents an optimization of the detection coil of high-T c superconducting quantum interference device (SQUID)-based nuclear magnetic resonance (NMR) in microtesla fields for discriminating a minimum amount of liver tumor in rats by characterizing the longitudinal relaxation rate, T1-1, of tested samples. The detection coil, which was coupled to the SQUID through a flux transformer, was optimized by varying the copper wires' winding turns and diameters. When comparing the measured NMR signals, we found that the simulated NMR signal agrees with simulated signals. When discriminating liver tumors in rats, the averaged longitudinal relaxation rate was observed to be T1-1 = 3.3 s-1 for cancerous liver tissue and T1-1 = 6.6 s-1 for normal liver tissue. The results suggest that it can be used to successfully discriminate cancerous liver tissue from normal liver tissues in rats. The minimum amount of samples that can be detected is 0.2 g for liver tumor and 0.4 g for normal liver tissue in 100 μT fields. The specimen was not damaged; it can be used for other pathological analyses. The proposed method provides more possibilities for examining undersized specimens.",
author = "Chen, {Hsin Hsien} and Huang, {Kai Wen} and Hong-Chang Yang and Herng-Er Horng and Shu-Hsien Liao",
year = "2013",
month = "8",
day = "14",
doi = "10.1063/1.4817886",
language = "English",
volume = "114",
journal = "Journal of Applied Physics",
issn = "0021-8979",
publisher = "American Institute of Physics Publising LLC",
number = "6",

}

TY - JOUR

T1 - Optimization of the detection coil of high-Tc superconducting quantum interference device-based nuclear magnetic resonance for discriminating a minimum amount of liver tumor of rats in microtesla fields

AU - Chen, Hsin Hsien

AU - Huang, Kai Wen

AU - Yang, Hong-Chang

AU - Horng, Herng-Er

AU - Liao, Shu-Hsien

PY - 2013/8/14

Y1 - 2013/8/14

N2 - This study presents an optimization of the detection coil of high-T c superconducting quantum interference device (SQUID)-based nuclear magnetic resonance (NMR) in microtesla fields for discriminating a minimum amount of liver tumor in rats by characterizing the longitudinal relaxation rate, T1-1, of tested samples. The detection coil, which was coupled to the SQUID through a flux transformer, was optimized by varying the copper wires' winding turns and diameters. When comparing the measured NMR signals, we found that the simulated NMR signal agrees with simulated signals. When discriminating liver tumors in rats, the averaged longitudinal relaxation rate was observed to be T1-1 = 3.3 s-1 for cancerous liver tissue and T1-1 = 6.6 s-1 for normal liver tissue. The results suggest that it can be used to successfully discriminate cancerous liver tissue from normal liver tissues in rats. The minimum amount of samples that can be detected is 0.2 g for liver tumor and 0.4 g for normal liver tissue in 100 μT fields. The specimen was not damaged; it can be used for other pathological analyses. The proposed method provides more possibilities for examining undersized specimens.

AB - This study presents an optimization of the detection coil of high-T c superconducting quantum interference device (SQUID)-based nuclear magnetic resonance (NMR) in microtesla fields for discriminating a minimum amount of liver tumor in rats by characterizing the longitudinal relaxation rate, T1-1, of tested samples. The detection coil, which was coupled to the SQUID through a flux transformer, was optimized by varying the copper wires' winding turns and diameters. When comparing the measured NMR signals, we found that the simulated NMR signal agrees with simulated signals. When discriminating liver tumors in rats, the averaged longitudinal relaxation rate was observed to be T1-1 = 3.3 s-1 for cancerous liver tissue and T1-1 = 6.6 s-1 for normal liver tissue. The results suggest that it can be used to successfully discriminate cancerous liver tissue from normal liver tissues in rats. The minimum amount of samples that can be detected is 0.2 g for liver tumor and 0.4 g for normal liver tissue in 100 μT fields. The specimen was not damaged; it can be used for other pathological analyses. The proposed method provides more possibilities for examining undersized specimens.

UR - http://www.scopus.com/inward/record.url?scp=84883412689&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84883412689&partnerID=8YFLogxK

U2 - 10.1063/1.4817886

DO - 10.1063/1.4817886

M3 - Article

AN - SCOPUS:84883412689

VL - 114

JO - Journal of Applied Physics

JF - Journal of Applied Physics

SN - 0021-8979

IS - 6

M1 - 064701

ER -