In contrast to the type of two-sample measurement used in conventional nephelometric immunoassay, a methodology to achieve a one-sample nephelometric immunoassay is developed in this work. Magnetic nanoparticles instead of latex particles are used as scattering centers. The experimental results show that the sensitivity of assaying avidin or c-reactive protein increased about three times under the action of the magnetic field in nephelometric immunoassay using magnetic nanoparticles.

Original languageEnglish
Article number244102
JournalApplied Physics Letters
Volume89
Issue number24
DOIs
Publication statusPublished - 2006 Dec 29

Fingerprint

immunoassay
nanoparticles
assaying
lasers
latex
methodology
proteins
sensitivity
scattering
magnetic fields

ASJC Scopus subject areas

  • Physics and Astronomy (miscellaneous)

Cite this

One-sample measurement in laser nephelometric immunoassay using magnetic nanoparticles. / Yang, S. Y.; Wu, R. M.; Jian, Z. F.; Horng, H. E.; Hong, Chin Yih; Yang, H. C.

In: Applied Physics Letters, Vol. 89, No. 24, 244102, 29.12.2006.

Research output: Contribution to journalArticle

Yang, S. Y. ; Wu, R. M. ; Jian, Z. F. ; Horng, H. E. ; Hong, Chin Yih ; Yang, H. C. / One-sample measurement in laser nephelometric immunoassay using magnetic nanoparticles. In: Applied Physics Letters. 2006 ; Vol. 89, No. 24.
@article{15ab974d6bcf48c8a172bf1e185113c2,
title = "One-sample measurement in laser nephelometric immunoassay using magnetic nanoparticles",
abstract = "In contrast to the type of two-sample measurement used in conventional nephelometric immunoassay, a methodology to achieve a one-sample nephelometric immunoassay is developed in this work. Magnetic nanoparticles instead of latex particles are used as scattering centers. The experimental results show that the sensitivity of assaying avidin or c-reactive protein increased about three times under the action of the magnetic field in nephelometric immunoassay using magnetic nanoparticles.",
author = "Yang, {S. Y.} and Wu, {R. M.} and Jian, {Z. F.} and Horng, {H. E.} and Hong, {Chin Yih} and Yang, {H. C.}",
year = "2006",
month = "12",
day = "29",
doi = "10.1063/1.2405409",
language = "English",
volume = "89",
journal = "Applied Physics Letters",
issn = "0003-6951",
publisher = "American Institute of Physics Publising LLC",
number = "24",

}

TY - JOUR

T1 - One-sample measurement in laser nephelometric immunoassay using magnetic nanoparticles

AU - Yang, S. Y.

AU - Wu, R. M.

AU - Jian, Z. F.

AU - Horng, H. E.

AU - Hong, Chin Yih

AU - Yang, H. C.

PY - 2006/12/29

Y1 - 2006/12/29

N2 - In contrast to the type of two-sample measurement used in conventional nephelometric immunoassay, a methodology to achieve a one-sample nephelometric immunoassay is developed in this work. Magnetic nanoparticles instead of latex particles are used as scattering centers. The experimental results show that the sensitivity of assaying avidin or c-reactive protein increased about three times under the action of the magnetic field in nephelometric immunoassay using magnetic nanoparticles.

AB - In contrast to the type of two-sample measurement used in conventional nephelometric immunoassay, a methodology to achieve a one-sample nephelometric immunoassay is developed in this work. Magnetic nanoparticles instead of latex particles are used as scattering centers. The experimental results show that the sensitivity of assaying avidin or c-reactive protein increased about three times under the action of the magnetic field in nephelometric immunoassay using magnetic nanoparticles.

UR - http://www.scopus.com/inward/record.url?scp=33845797048&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33845797048&partnerID=8YFLogxK

U2 - 10.1063/1.2405409

DO - 10.1063/1.2405409

M3 - Article

AN - SCOPUS:33845797048

VL - 89

JO - Applied Physics Letters

JF - Applied Physics Letters

SN - 0003-6951

IS - 24

M1 - 244102

ER -