TY - JOUR
T1 - Multiple-stage microfabricated preconcentrator-focuser for micro gas chromatography system
AU - Tian, Wei Cheng
AU - Chan, Helena K.L.
AU - Lu, Chia Jung
AU - Pang, Stella W.
AU - Zellers, Edward T.
N1 - Funding Information:
Manuscript received February 19, 2004; revised October 10, 2004. This work was supported through the University of Michigan Engineering Research Center for Wireless Integrated Microsystems (WIMS) by the Engineering Research Centers Program of the National Science Foundation under Award Number ERC-9986866. Subject Editor T. Kenny.
PY - 2005/6
Y1 - 2005/6
N2 - The design, fabrication, and characterization of a multiple-stage Si microfabricated preconcentrator-focuser (μPCF) for a micro gas chromatography (μGC) system that can provide real-time quantification and identification of complex organic vapor mixtures are presented. The μPCF consists of a Si microheater loaded with Carbopack B, Carbopack X, and Carboxen 1000 carbon adsorbent granules, and a Si micromachined cover plate. Deep reactive ion etching is utilized to produce mechanically robust fluidic interconnection adapters hermetically sealed to fused silica capillary tubing for connection to the other components in the μGC. This three-stage device is designed to capture compounds spanning up to 4 orders of magnitude in volatility. The dead volume, thermal mass, heating efficiency, and pressure drop of the three-stage μPCF are improved significantly over its single-stage μPCF predecessor. We demonstrate the successful capture, desorption, and high-resolution chromatographic separation of a mixture of 30 common organic vapors using our three-stage μPCF in a conventional GC system. The peak width at half height is <2.05 s for all compounds after elution from the GC column.
AB - The design, fabrication, and characterization of a multiple-stage Si microfabricated preconcentrator-focuser (μPCF) for a micro gas chromatography (μGC) system that can provide real-time quantification and identification of complex organic vapor mixtures are presented. The μPCF consists of a Si microheater loaded with Carbopack B, Carbopack X, and Carboxen 1000 carbon adsorbent granules, and a Si micromachined cover plate. Deep reactive ion etching is utilized to produce mechanically robust fluidic interconnection adapters hermetically sealed to fused silica capillary tubing for connection to the other components in the μGC. This three-stage device is designed to capture compounds spanning up to 4 orders of magnitude in volatility. The dead volume, thermal mass, heating efficiency, and pressure drop of the three-stage μPCF are improved significantly over its single-stage μPCF predecessor. We demonstrate the successful capture, desorption, and high-resolution chromatographic separation of a mixture of 30 common organic vapors using our three-stage μPCF in a conventional GC system. The peak width at half height is <2.05 s for all compounds after elution from the GC column.
KW - Adsorbent
KW - Gas detection
KW - Micro gas chromatography (μGC)
KW - Micro-heater
KW - Microelectromechanical systems (MEMS)
KW - Preconcentrator-focuser (PCF)
UR - http://www.scopus.com/inward/record.url?scp=22444451077&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=22444451077&partnerID=8YFLogxK
U2 - 10.1109/JMEMS.2005.844842
DO - 10.1109/JMEMS.2005.844842
M3 - Article
AN - SCOPUS:22444451077
SN - 1057-7157
VL - 14
SP - 498
EP - 507
JO - Journal of Microelectromechanical Systems
JF - Journal of Microelectromechanical Systems
IS - 3
ER -