Measuring real-time concentration trends of individual VOC in an elementary school using a sub-ppb detection μGC and a single GC-MS analysis

Rih Sheng Jian, Lung Yu Sung, Chia-Jung Lu

Research output: Contribution to journalArticle

11 Citations (Scopus)

Abstract

This paper reports the results from a field study that used a micro gas chromatograph (μGC) in conjunction with single gas chromatography-mass spectrometry (GC-MS) analysis to obtain the time-dependent concentration changes of individual volatile organic compounds (VOCs). The μGC is capable of performing sub-ppb analysis every 15. min and has a total weight of only 3. kg, which includes an embedded tablet computer. The field study was conducted in an elementary school near a chemical industrial area. Six VOCs including acetone, 2-butanone, methyl acetate, toluene, m-xylene and isobutyl acetate, were detected at low ppb levels via canister/GC-MS analysis. Five of the six chemicals were successfully quantified using the μGC. The lone exception was acetone, which prematurely breakthrough on the preconcentrator of the μGC because of its high volatility. The continuous analyses performed by the μGC revealed the individual temporal trends of the concentrations for the remaining 5 chemicals. The establishment of real-time trends for each of the chemicals enabled a detailed examination of their correlations.

Original languageEnglish
Pages (from-to)261-266
Number of pages6
JournalChemosphere
Volume99
DOIs
Publication statusPublished - 2014 Mar 1

Fingerprint

Volatile Organic Compounds
Volatile organic compounds
volatile organic compound
Gases
gas
Acetone
acetone
acetate
Handheld Computers
Industrial chemicals
Volatilization
Toluene
xylene
Xylene
Gas chromatography
toluene
Gas Chromatography-Mass Spectrometry
Tablets
Mass spectrometry
measuring

Keywords

  • Environmental monitoring
  • Micro gas chromatograph
  • Real-time analysis
  • Volatile organic compounds

ASJC Scopus subject areas

  • Environmental Engineering
  • Environmental Chemistry
  • Chemistry(all)
  • Pollution
  • Health, Toxicology and Mutagenesis

Cite this

Measuring real-time concentration trends of individual VOC in an elementary school using a sub-ppb detection μGC and a single GC-MS analysis. / Jian, Rih Sheng; Sung, Lung Yu; Lu, Chia-Jung.

In: Chemosphere, Vol. 99, 01.03.2014, p. 261-266.

Research output: Contribution to journalArticle

@article{24f2c160626d40d8bd361b1e1bcda1ee,
title = "Measuring real-time concentration trends of individual VOC in an elementary school using a sub-ppb detection μGC and a single GC-MS analysis",
abstract = "This paper reports the results from a field study that used a micro gas chromatograph (μGC) in conjunction with single gas chromatography-mass spectrometry (GC-MS) analysis to obtain the time-dependent concentration changes of individual volatile organic compounds (VOCs). The μGC is capable of performing sub-ppb analysis every 15. min and has a total weight of only 3. kg, which includes an embedded tablet computer. The field study was conducted in an elementary school near a chemical industrial area. Six VOCs including acetone, 2-butanone, methyl acetate, toluene, m-xylene and isobutyl acetate, were detected at low ppb levels via canister/GC-MS analysis. Five of the six chemicals were successfully quantified using the μGC. The lone exception was acetone, which prematurely breakthrough on the preconcentrator of the μGC because of its high volatility. The continuous analyses performed by the μGC revealed the individual temporal trends of the concentrations for the remaining 5 chemicals. The establishment of real-time trends for each of the chemicals enabled a detailed examination of their correlations.",
keywords = "Environmental monitoring, Micro gas chromatograph, Real-time analysis, Volatile organic compounds",
author = "Jian, {Rih Sheng} and Sung, {Lung Yu} and Chia-Jung Lu",
year = "2014",
month = "3",
day = "1",
doi = "10.1016/j.chemosphere.2013.10.094",
language = "English",
volume = "99",
pages = "261--266",
journal = "Chemosphere",
issn = "0045-6535",
publisher = "Elsevier Limited",

}

TY - JOUR

T1 - Measuring real-time concentration trends of individual VOC in an elementary school using a sub-ppb detection μGC and a single GC-MS analysis

AU - Jian, Rih Sheng

AU - Sung, Lung Yu

AU - Lu, Chia-Jung

PY - 2014/3/1

Y1 - 2014/3/1

N2 - This paper reports the results from a field study that used a micro gas chromatograph (μGC) in conjunction with single gas chromatography-mass spectrometry (GC-MS) analysis to obtain the time-dependent concentration changes of individual volatile organic compounds (VOCs). The μGC is capable of performing sub-ppb analysis every 15. min and has a total weight of only 3. kg, which includes an embedded tablet computer. The field study was conducted in an elementary school near a chemical industrial area. Six VOCs including acetone, 2-butanone, methyl acetate, toluene, m-xylene and isobutyl acetate, were detected at low ppb levels via canister/GC-MS analysis. Five of the six chemicals were successfully quantified using the μGC. The lone exception was acetone, which prematurely breakthrough on the preconcentrator of the μGC because of its high volatility. The continuous analyses performed by the μGC revealed the individual temporal trends of the concentrations for the remaining 5 chemicals. The establishment of real-time trends for each of the chemicals enabled a detailed examination of their correlations.

AB - This paper reports the results from a field study that used a micro gas chromatograph (μGC) in conjunction with single gas chromatography-mass spectrometry (GC-MS) analysis to obtain the time-dependent concentration changes of individual volatile organic compounds (VOCs). The μGC is capable of performing sub-ppb analysis every 15. min and has a total weight of only 3. kg, which includes an embedded tablet computer. The field study was conducted in an elementary school near a chemical industrial area. Six VOCs including acetone, 2-butanone, methyl acetate, toluene, m-xylene and isobutyl acetate, were detected at low ppb levels via canister/GC-MS analysis. Five of the six chemicals were successfully quantified using the μGC. The lone exception was acetone, which prematurely breakthrough on the preconcentrator of the μGC because of its high volatility. The continuous analyses performed by the μGC revealed the individual temporal trends of the concentrations for the remaining 5 chemicals. The establishment of real-time trends for each of the chemicals enabled a detailed examination of their correlations.

KW - Environmental monitoring

KW - Micro gas chromatograph

KW - Real-time analysis

KW - Volatile organic compounds

UR - http://www.scopus.com/inward/record.url?scp=84893777410&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84893777410&partnerID=8YFLogxK

U2 - 10.1016/j.chemosphere.2013.10.094

DO - 10.1016/j.chemosphere.2013.10.094

M3 - Article

C2 - 24314896

AN - SCOPUS:84893777410

VL - 99

SP - 261

EP - 266

JO - Chemosphere

JF - Chemosphere

SN - 0045-6535

ER -