TY - GEN
T1 - Magnetic assistance for suppressing cross-reactions between biomolecules in immunoassay
AU - Hong, Chin Yih
AU - Yang, Shieh Yueh
AU - Horng, Herng Er
AU - Yang, Hong Chang
PY - 2010
Y1 - 2010
N2 - A method involving the use of magnetic nanoparticles to suppress the cross-reactions in immunoassay is developed. Antibodies are coated onto magnetic nanoparticles. These antibodies bind with target and non-target molecules. Once an alternative-current magnetic field is applied, magnetic nanoparticles oscillate with the magnetic field. The target and non-target molecules attached onto magnetic nanoparticles via antibodies experience a centrifugal force, which is against the association between antibodies and target/non-target molecules. Theoretically, the centrifugal force is proportional to the square of the frequency of the applied magnetic field. Thus, the strength of the centrifugal force can be manipulated by changing the frequency of the applied magnetic field. By well controlling the frequency of applied magnetic field, the centrifugal force can be stronger than the binding between antibodies and non-target molecules, but still weaker than that of target molecules. Consequently, the binding between antibodies and non-target molecules is broken by the centrifugal force.
AB - A method involving the use of magnetic nanoparticles to suppress the cross-reactions in immunoassay is developed. Antibodies are coated onto magnetic nanoparticles. These antibodies bind with target and non-target molecules. Once an alternative-current magnetic field is applied, magnetic nanoparticles oscillate with the magnetic field. The target and non-target molecules attached onto magnetic nanoparticles via antibodies experience a centrifugal force, which is against the association between antibodies and target/non-target molecules. Theoretically, the centrifugal force is proportional to the square of the frequency of the applied magnetic field. Thus, the strength of the centrifugal force can be manipulated by changing the frequency of the applied magnetic field. By well controlling the frequency of applied magnetic field, the centrifugal force can be stronger than the binding between antibodies and non-target molecules, but still weaker than that of target molecules. Consequently, the binding between antibodies and non-target molecules is broken by the centrifugal force.
UR - http://www.scopus.com/inward/record.url?scp=80054967888&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=80054967888&partnerID=8YFLogxK
U2 - 10.1115/DETC2010-28040
DO - 10.1115/DETC2010-28040
M3 - Conference contribution
AN - SCOPUS:80054967888
SN - 9780791844120
T3 - Proceedings of the ASME Design Engineering Technical Conference
SP - 393
EP - 396
BT - ASME 2010 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference, IDETC/CIE2010
T2 - ASME 2010 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference, IDETC/CIE2010
Y2 - 15 August 2010 through 18 August 2010
ER -