In-vitro diagnosis of colon cancer using bio-functionalized magnetic nanoparticles

Chin Yih Hong, Shieh-Yueh Yang, K. W. Huang, Herng-Er Horng, Hong-Chang Yang

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

The popular bio-marker for colon cancer is carcinoembryonic antigen (CEA). By conjugating anti-CEA onto magnetic nanoparticles, CEA can be specially labeled and detected by measuring magnetic signals via immunomagnetic reduction (IMR). The low detection limit and detection range of IMR on CEA are investigated. The results are compared with those by using the existing assay, such as enzyme-linked immunosorbent assay (ELISA). It is evidenced that IMR has sensitivity much higher than that of ELISA. The low detection limit is below the normal level of CEA concentration of clinic practice and is suitable for early-stage in-vitro diagnosis for colon cancer. Furthermore, the dynamic range of detection for the CEA concentration using IMR extends well above the threshold of high risk level of colorectal carcinoma in current diagnosing practice. Therefore, IMR is also suitable in other stages diagnosis for colon cancer development.

Original languageEnglish
Title of host publicationASME 2011 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference, IDETC/CIE 2011
Pages11-15
Number of pages5
DOIs
Publication statusPublished - 2011 Dec 1
EventASME 2011 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference, IDETC/CIE 2011 - Washington, DC, United States
Duration: 2011 Aug 282011 Aug 31

Publication series

NameProceedings of the ASME Design Engineering Technical Conference
Volume7

Other

OtherASME 2011 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference, IDETC/CIE 2011
CountryUnited States
CityWashington, DC
Period11/8/2811/8/31

Fingerprint

Magnetic Nanoparticles
Antigens
Cancer
Nanoparticles
Enzyme-linked Immunosorbent Assay
Detection Limit
Assays
Enzymes
Biomarkers
Dynamic Range
Range of data

Keywords

  • Carcinoembryonic antigen
  • Colorectal carcinoma
  • Enzyme-linked immunosorbent assay
  • Immunomagnetic reduction

ASJC Scopus subject areas

  • Modelling and Simulation
  • Mechanical Engineering
  • Computer Science Applications
  • Computer Graphics and Computer-Aided Design

Cite this

Hong, C. Y., Yang, S-Y., Huang, K. W., Horng, H-E., & Yang, H-C. (2011). In-vitro diagnosis of colon cancer using bio-functionalized magnetic nanoparticles. In ASME 2011 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference, IDETC/CIE 2011 (pp. 11-15). (Proceedings of the ASME Design Engineering Technical Conference; Vol. 7). https://doi.org/10.1115/DETC2011-47178

In-vitro diagnosis of colon cancer using bio-functionalized magnetic nanoparticles. / Hong, Chin Yih; Yang, Shieh-Yueh; Huang, K. W.; Horng, Herng-Er; Yang, Hong-Chang.

ASME 2011 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference, IDETC/CIE 2011. 2011. p. 11-15 (Proceedings of the ASME Design Engineering Technical Conference; Vol. 7).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Hong, CY, Yang, S-Y, Huang, KW, Horng, H-E & Yang, H-C 2011, In-vitro diagnosis of colon cancer using bio-functionalized magnetic nanoparticles. in ASME 2011 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference, IDETC/CIE 2011. Proceedings of the ASME Design Engineering Technical Conference, vol. 7, pp. 11-15, ASME 2011 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference, IDETC/CIE 2011, Washington, DC, United States, 11/8/28. https://doi.org/10.1115/DETC2011-47178
Hong CY, Yang S-Y, Huang KW, Horng H-E, Yang H-C. In-vitro diagnosis of colon cancer using bio-functionalized magnetic nanoparticles. In ASME 2011 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference, IDETC/CIE 2011. 2011. p. 11-15. (Proceedings of the ASME Design Engineering Technical Conference). https://doi.org/10.1115/DETC2011-47178
Hong, Chin Yih ; Yang, Shieh-Yueh ; Huang, K. W. ; Horng, Herng-Er ; Yang, Hong-Chang. / In-vitro diagnosis of colon cancer using bio-functionalized magnetic nanoparticles. ASME 2011 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference, IDETC/CIE 2011. 2011. pp. 11-15 (Proceedings of the ASME Design Engineering Technical Conference).
@inproceedings{558d0ef669f14edeb613f3f61a999e77,
title = "In-vitro diagnosis of colon cancer using bio-functionalized magnetic nanoparticles",
abstract = "The popular bio-marker for colon cancer is carcinoembryonic antigen (CEA). By conjugating anti-CEA onto magnetic nanoparticles, CEA can be specially labeled and detected by measuring magnetic signals via immunomagnetic reduction (IMR). The low detection limit and detection range of IMR on CEA are investigated. The results are compared with those by using the existing assay, such as enzyme-linked immunosorbent assay (ELISA). It is evidenced that IMR has sensitivity much higher than that of ELISA. The low detection limit is below the normal level of CEA concentration of clinic practice and is suitable for early-stage in-vitro diagnosis for colon cancer. Furthermore, the dynamic range of detection for the CEA concentration using IMR extends well above the threshold of high risk level of colorectal carcinoma in current diagnosing practice. Therefore, IMR is also suitable in other stages diagnosis for colon cancer development.",
keywords = "Carcinoembryonic antigen, Colorectal carcinoma, Enzyme-linked immunosorbent assay, Immunomagnetic reduction",
author = "Hong, {Chin Yih} and Shieh-Yueh Yang and Huang, {K. W.} and Herng-Er Horng and Hong-Chang Yang",
year = "2011",
month = "12",
day = "1",
doi = "10.1115/DETC2011-47178",
language = "English",
isbn = "9780791854846",
series = "Proceedings of the ASME Design Engineering Technical Conference",
pages = "11--15",
booktitle = "ASME 2011 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference, IDETC/CIE 2011",

}

TY - GEN

T1 - In-vitro diagnosis of colon cancer using bio-functionalized magnetic nanoparticles

AU - Hong, Chin Yih

AU - Yang, Shieh-Yueh

AU - Huang, K. W.

AU - Horng, Herng-Er

AU - Yang, Hong-Chang

PY - 2011/12/1

Y1 - 2011/12/1

N2 - The popular bio-marker for colon cancer is carcinoembryonic antigen (CEA). By conjugating anti-CEA onto magnetic nanoparticles, CEA can be specially labeled and detected by measuring magnetic signals via immunomagnetic reduction (IMR). The low detection limit and detection range of IMR on CEA are investigated. The results are compared with those by using the existing assay, such as enzyme-linked immunosorbent assay (ELISA). It is evidenced that IMR has sensitivity much higher than that of ELISA. The low detection limit is below the normal level of CEA concentration of clinic practice and is suitable for early-stage in-vitro diagnosis for colon cancer. Furthermore, the dynamic range of detection for the CEA concentration using IMR extends well above the threshold of high risk level of colorectal carcinoma in current diagnosing practice. Therefore, IMR is also suitable in other stages diagnosis for colon cancer development.

AB - The popular bio-marker for colon cancer is carcinoembryonic antigen (CEA). By conjugating anti-CEA onto magnetic nanoparticles, CEA can be specially labeled and detected by measuring magnetic signals via immunomagnetic reduction (IMR). The low detection limit and detection range of IMR on CEA are investigated. The results are compared with those by using the existing assay, such as enzyme-linked immunosorbent assay (ELISA). It is evidenced that IMR has sensitivity much higher than that of ELISA. The low detection limit is below the normal level of CEA concentration of clinic practice and is suitable for early-stage in-vitro diagnosis for colon cancer. Furthermore, the dynamic range of detection for the CEA concentration using IMR extends well above the threshold of high risk level of colorectal carcinoma in current diagnosing practice. Therefore, IMR is also suitable in other stages diagnosis for colon cancer development.

KW - Carcinoembryonic antigen

KW - Colorectal carcinoma

KW - Enzyme-linked immunosorbent assay

KW - Immunomagnetic reduction

UR - http://www.scopus.com/inward/record.url?scp=84863591990&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84863591990&partnerID=8YFLogxK

U2 - 10.1115/DETC2011-47178

DO - 10.1115/DETC2011-47178

M3 - Conference contribution

AN - SCOPUS:84863591990

SN - 9780791854846

T3 - Proceedings of the ASME Design Engineering Technical Conference

SP - 11

EP - 15

BT - ASME 2011 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference, IDETC/CIE 2011

ER -