Immunoassay-amplified responses using a functionalized mos2-based spr biosensor to detect papp-a2 in maternal serum samples to screen for fetal down’s syndrome

Nan Fu Chiu*, Ming Jung Tai, Devi Taufiq Nurrohman, Ting Li Lin, Ying Hao Wang, Chen Yu Chen*

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

29 Citations (Scopus)

Abstract

Background: Due to educational, social and economic reasons, more and more women are delaying childbirth. However, advanced maternal age is associated with several adverse pregnancy outcomes, and in particular a high risk of Down’s syndrome (DS). Hence, it is increasingly important to be able to detect fetal Down’s syndrome (FDS). Methods: We developed an effective, highly sensitive, surface plasmon resonance (SPR) biosensor with biochemically amplified responses using carboxyl-molybdenum disulfide (MoS2) film. The use of carboxylic acid as a surface modifier of MoS2 promoted dispersion and formed specific three-dimensional coordination sites. The carboxylic acid immobilized unmodified antibodies in a way that enhanced the bioaffinity of MoS2 and preserved biorecognition properties of the SPR sensor surface. Complete antigen pregnancy-associated plasma protein-A2 (PAPP-A2) conjugated with the carboxyl-MoS2-modified gold chip to amplify the signal and improve detection sensitivity. This heterostructure interface had a high work function, and thus improved the efficiency of the electric field energy of the surface plasmon. These results provide evidence that the interface electric field improved performance of the SPR biosensor. Results: The carboxyl-MoS2-based SPR biosensor was used successfully to evaluate PAPP-A2 level for fetal Down’s syndrome screening in maternal serum samples. The detection limit was 0.05 pg/mL, and the linear working range was 0.1 to 1100 pg/mL. The women with an SPR angle >46.57 m° were more closely associated with fetal Down’s syndrome. Once optimized for serum Down’s syndrome screening, an average recovery of 95.2% and relative standard deviation of 8.5% were obtained. Our findings suggest that carboxyl-MoS2-based SPR technology may have advantages over conven-tional ELISA in certain situations. Conclusion: Carboxyl-MoS2-based SPR biosensors can be used as a new diagnostic technology to respond to the increasing need for fetal Down’s syndrome screening in maternal serum samples. Our results demonstrated that the carboxyl-MoS2-based SPR biosensor was capable of determining PAPP-A2 levels with acceptable accuracy and recovery. We hope that this technology will be investigated in diverse clinical trials and in real case applications for screening and early diagnosis in the future.

Original languageEnglish
Pages (from-to)2715-2733
Number of pages19
JournalInternational Journal of Nanomedicine
Volume16
DOIs
Publication statusPublished - 2021

Keywords

  • Carboxyl-MoS
  • Carboxyl-functionalized molybdenum disulfide
  • DS
  • Down’s syndrome
  • FDS
  • Fetal Down’s syndrome
  • PAPP-A2
  • Pregnancy-associated plasma protein A2
  • SPR
  • Surface plasmon resonance

ASJC Scopus subject areas

  • Biophysics
  • Bioengineering
  • Biomaterials
  • Pharmaceutical Science
  • Drug Discovery
  • Organic Chemistry

Fingerprint

Dive into the research topics of 'Immunoassay-amplified responses using a functionalized mos2-based spr biosensor to detect papp-a2 in maternal serum samples to screen for fetal down’s syndrome'. Together they form a unique fingerprint.

Cite this