High-Tc SQUID magnetocardiography imaging system.

H. C. Yang, S. Y. Hung, C. H. Wu, J. C. Chen, S. J. Hsu, S. H. Liao, H. E. Horng

    Research output: Contribution to journalArticle

    Abstract

    We set up a high-Tc SQUID system for magnetocardiography (MCG) in a moderately magnetically shielded room. The electronically balanced gradiometer consists of superconducting quantum interference device (SQUID) magnetometer. One reference SQUID was mounted above the sensing SQUID while the sensing SQUID is seated at the bottom of the cryostat. The baseline of the gradiometer is varied from 5 cm to 7 cm. The output of the MCG signal was filtered with the band pass filter (0.5 - 40 Hz) and the power-line filter. The MCG system was used to detect the magnetic signal of the human heart. Equivalent current sources were used to study the inverse problem.

    Original languageEnglish
    Number of pages1
    JournalNeurology & clinical neurophysiology : NCN
    Volume2004
    Publication statusPublished - 2004 Jan 1

    Fingerprint

    Magnetocardiography
    Equipment and Supplies

    ASJC Scopus subject areas

    • Neuroscience(all)

    Cite this

    Yang, H. C., Hung, S. Y., Wu, C. H., Chen, J. C., Hsu, S. J., Liao, S. H., & Horng, H. E. (2004). High-Tc SQUID magnetocardiography imaging system. Neurology & clinical neurophysiology : NCN, 2004.

    High-Tc SQUID magnetocardiography imaging system. / Yang, H. C.; Hung, S. Y.; Wu, C. H.; Chen, J. C.; Hsu, S. J.; Liao, S. H.; Horng, H. E.

    In: Neurology & clinical neurophysiology : NCN, Vol. 2004, 01.01.2004.

    Research output: Contribution to journalArticle

    Yang, HC, Hung, SY, Wu, CH, Chen, JC, Hsu, SJ, Liao, SH & Horng, HE 2004, 'High-Tc SQUID magnetocardiography imaging system.', Neurology & clinical neurophysiology : NCN, vol. 2004.
    Yang HC, Hung SY, Wu CH, Chen JC, Hsu SJ, Liao SH et al. High-Tc SQUID magnetocardiography imaging system. Neurology & clinical neurophysiology : NCN. 2004 Jan 1;2004.
    Yang, H. C. ; Hung, S. Y. ; Wu, C. H. ; Chen, J. C. ; Hsu, S. J. ; Liao, S. H. ; Horng, H. E. / High-Tc SQUID magnetocardiography imaging system. In: Neurology & clinical neurophysiology : NCN. 2004 ; Vol. 2004.
    @article{f76f31851b9e4790b8a0558e0c3ecb1d,
    title = "High-Tc SQUID magnetocardiography imaging system.",
    abstract = "We set up a high-Tc SQUID system for magnetocardiography (MCG) in a moderately magnetically shielded room. The electronically balanced gradiometer consists of superconducting quantum interference device (SQUID) magnetometer. One reference SQUID was mounted above the sensing SQUID while the sensing SQUID is seated at the bottom of the cryostat. The baseline of the gradiometer is varied from 5 cm to 7 cm. The output of the MCG signal was filtered with the band pass filter (0.5 - 40 Hz) and the power-line filter. The MCG system was used to detect the magnetic signal of the human heart. Equivalent current sources were used to study the inverse problem.",
    author = "Yang, {H. C.} and Hung, {S. Y.} and Wu, {C. H.} and Chen, {J. C.} and Hsu, {S. J.} and Liao, {S. H.} and Horng, {H. E.}",
    year = "2004",
    month = "1",
    day = "1",
    language = "English",
    volume = "2004",
    journal = "Neurology & clinical neurophysiology [electronic resource] : NCN.",
    issn = "1526-8748",
    publisher = "American Academy of Clinical Neurophysiology",

    }

    TY - JOUR

    T1 - High-Tc SQUID magnetocardiography imaging system.

    AU - Yang, H. C.

    AU - Hung, S. Y.

    AU - Wu, C. H.

    AU - Chen, J. C.

    AU - Hsu, S. J.

    AU - Liao, S. H.

    AU - Horng, H. E.

    PY - 2004/1/1

    Y1 - 2004/1/1

    N2 - We set up a high-Tc SQUID system for magnetocardiography (MCG) in a moderately magnetically shielded room. The electronically balanced gradiometer consists of superconducting quantum interference device (SQUID) magnetometer. One reference SQUID was mounted above the sensing SQUID while the sensing SQUID is seated at the bottom of the cryostat. The baseline of the gradiometer is varied from 5 cm to 7 cm. The output of the MCG signal was filtered with the band pass filter (0.5 - 40 Hz) and the power-line filter. The MCG system was used to detect the magnetic signal of the human heart. Equivalent current sources were used to study the inverse problem.

    AB - We set up a high-Tc SQUID system for magnetocardiography (MCG) in a moderately magnetically shielded room. The electronically balanced gradiometer consists of superconducting quantum interference device (SQUID) magnetometer. One reference SQUID was mounted above the sensing SQUID while the sensing SQUID is seated at the bottom of the cryostat. The baseline of the gradiometer is varied from 5 cm to 7 cm. The output of the MCG signal was filtered with the band pass filter (0.5 - 40 Hz) and the power-line filter. The MCG system was used to detect the magnetic signal of the human heart. Equivalent current sources were used to study the inverse problem.

    UR - http://www.scopus.com/inward/record.url?scp=33645732190&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=33645732190&partnerID=8YFLogxK

    M3 - Article

    C2 - 16012658

    VL - 2004

    JO - Neurology & clinical neurophysiology [electronic resource] : NCN.

    JF - Neurology & clinical neurophysiology [electronic resource] : NCN.

    SN - 1526-8748

    ER -