TY - JOUR
T1 - Graphene oxide-based SPR biosensor chip for immunoassay applications
AU - Chiu, Nan Fu
AU - Huang, Teng Yi
AU - Lai, Hsin Chih
AU - Liu, Kou Chen
N1 - Publisher Copyright:
© 2014, Chiu et al.; licensee Springer.
PY - 2014
Y1 - 2014
N2 - This work develops a highly sensitive immunoassay sensor for use in graphene oxide sheet (GOS)-based surface plasmon resonance (SPR) chips. This sensing film, which is formed by chemically modifying a GOS surface, has covalent bonds that strongly interact with the bovine serum albumin (BSA), explaining why it has a higher sensitivity. This GOS film-based SPR chip has a BSA concentration detection limit that is 100 times higher than that of the conventional Au-film-based sensor. The affinity constants (KA) on the GOS film-based SPR chip and the conventional SPR chip for 100 μg/ml BSA are 80.82 × 106 M-1 and 15.67 × 106 M-1, respectively. Therefore, the affinity constant of the GOS film-based SPR chip is 5.2 times higher than that of the conventional chip. With respect to the protein-protein interaction, the SPR sensor capability to detect angle changes at a low concentration anti-BSA of 75.75 nM on the GOS film-based SPR chip and the conventional SPR chip is 36.1867 and 26.1759 mdeg, respectively. At a high concentration, anti-BSA of 378.78 nM on the GOS film-based SPR chip and the conventional SPR chip reveals two times increases in the SPR angle shift. Above results demonstrate that the GOS film is promising for highly sensitive clinical diagnostic applications.
AB - This work develops a highly sensitive immunoassay sensor for use in graphene oxide sheet (GOS)-based surface plasmon resonance (SPR) chips. This sensing film, which is formed by chemically modifying a GOS surface, has covalent bonds that strongly interact with the bovine serum albumin (BSA), explaining why it has a higher sensitivity. This GOS film-based SPR chip has a BSA concentration detection limit that is 100 times higher than that of the conventional Au-film-based sensor. The affinity constants (KA) on the GOS film-based SPR chip and the conventional SPR chip for 100 μg/ml BSA are 80.82 × 106 M-1 and 15.67 × 106 M-1, respectively. Therefore, the affinity constant of the GOS film-based SPR chip is 5.2 times higher than that of the conventional chip. With respect to the protein-protein interaction, the SPR sensor capability to detect angle changes at a low concentration anti-BSA of 75.75 nM on the GOS film-based SPR chip and the conventional SPR chip is 36.1867 and 26.1759 mdeg, respectively. At a high concentration, anti-BSA of 378.78 nM on the GOS film-based SPR chip and the conventional SPR chip reveals two times increases in the SPR angle shift. Above results demonstrate that the GOS film is promising for highly sensitive clinical diagnostic applications.
KW - Bovine albumin serum (BSA)
KW - Graphene oxide sheet (GOS)
KW - Protein
KW - Surface plasmon resonance (SPR)
UR - http://www.scopus.com/inward/record.url?scp=84919946543&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84919946543&partnerID=8YFLogxK
U2 - 10.1186/1556-276X-9-445
DO - 10.1186/1556-276X-9-445
M3 - Article
AN - SCOPUS:84919946543
SN - 1931-7573
VL - 9
JO - Nanoscale Research Letters
JF - Nanoscale Research Letters
IS - 1
M1 - 445
ER -