Abstract

This study investigated the effect of a performance booster (PB) on the performance of a window-type air conditioner (WAC). The PB was fabricated using perforated aluminum plates with different pore size configurations according to the return air distribution of evaporator. The WAC was tested under various outdoor air conditions, and the performance of the WAC before and after PB installation was compared. Results showed that the PB effectively improved the performance of the WAC. The PB with three pore sizes improved the WAC performance more than the PB with two pore sizes. The maximum improvements in the WAC’s cooling capacity, dehumidification capacity, and energy efficiency ratio (EER) under the configuration with three pore sizes were 13.70 %, 59.63 % and 14.37 %, respectively, compared with the original WAC at an outdoor dry-bulb temperature of 30 °C.

Original languageEnglish
Pages (from-to)3955-3964
Number of pages10
JournalJournal of Mechanical Science and Technology
Volume32
Issue number8
DOIs
Publication statusPublished - 2018 Aug 1

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 7 - Affordable and Clean Energy
    SDG 7 Affordable and Clean Energy

Keywords

  • Cooling capacity
  • Dehumidification capacity
  • Energy efficiency ratio (EER)
  • Performance booster (PB)
  • Window-type air conditioner (WAC)

ASJC Scopus subject areas

  • Mechanics of Materials
  • Mechanical Engineering

Fingerprint

Dive into the research topics of 'Development of a performance booster for the evaporator of window-type air conditioners'. Together they form a unique fingerprint.

Cite this