Characterizing xBa (Mg 1/3 Ta 2/3 )O 3 + (1-x) Ba (Mg 1/3 Nb 2/3 )O 3 microwave ceramics using extended x-ray absorption fine structure method

P. J. Chang, Chi-Ta Chia, I. N. Lin, J. F. Lee, C. M. Lin, K. T. Wu

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

The structures of Ta O6 and Nb O6 oxygen octahedra in xBa (Mg13 Ta23) O3 + (1-x) Ba (Mg13 Nb23) O3 perovskite ceramics with x=0, 0.25, 0.50, 0.75, and 1.0 were investigated by the extended x-ray absorption fine structure method. The decline in the microwave dielectric constant as x increases is caused mainly by the decrease of the mean volume of the oxygen octahedra, regardless of the 1:2 ordered structure and the distortion of the oxygen octahedron. The low Qf values of the Ta O6 and Nb O6 mixed samples are caused by not only the degrading of the 1:2 ordered structure but also the distortion of oxygen octahedral cages.

Original languageEnglish
Article number242907
JournalApplied Physics Letters
Volume88
Issue number24
DOIs
Publication statusPublished - 2006 Jun 12

Fingerprint

x ray absorption
fine structure
ceramics
microwaves
oxygen
permittivity

ASJC Scopus subject areas

  • Physics and Astronomy (miscellaneous)

Cite this

Characterizing xBa (Mg 1/3 Ta 2/3 )O 3 + (1-x) Ba (Mg 1/3 Nb 2/3 )O 3 microwave ceramics using extended x-ray absorption fine structure method . / Chang, P. J.; Chia, Chi-Ta; Lin, I. N.; Lee, J. F.; Lin, C. M.; Wu, K. T.

In: Applied Physics Letters, Vol. 88, No. 24, 242907, 12.06.2006.

Research output: Contribution to journalArticle

@article{91d1d0c835874b5188ebf997c4c1a60a,
title = "Characterizing xBa (Mg 1/3 Ta 2/3 )O 3 + (1-x) Ba (Mg 1/3 Nb 2/3 )O 3 microwave ceramics using extended x-ray absorption fine structure method",
abstract = "The structures of Ta O6 and Nb O6 oxygen octahedra in xBa (Mg13 Ta23) O3 + (1-x) Ba (Mg13 Nb23) O3 perovskite ceramics with x=0, 0.25, 0.50, 0.75, and 1.0 were investigated by the extended x-ray absorption fine structure method. The decline in the microwave dielectric constant as x increases is caused mainly by the decrease of the mean volume of the oxygen octahedra, regardless of the 1:2 ordered structure and the distortion of the oxygen octahedron. The low Qf values of the Ta O6 and Nb O6 mixed samples are caused by not only the degrading of the 1:2 ordered structure but also the distortion of oxygen octahedral cages.",
author = "Chang, {P. J.} and Chi-Ta Chia and Lin, {I. N.} and Lee, {J. F.} and Lin, {C. M.} and Wu, {K. T.}",
year = "2006",
month = "6",
day = "12",
doi = "10.1063/1.2213514",
language = "English",
volume = "88",
journal = "Applied Physics Letters",
issn = "0003-6951",
publisher = "American Institute of Physics Publising LLC",
number = "24",

}

TY - JOUR

T1 - Characterizing xBa (Mg 1/3 Ta 2/3 )O 3 + (1-x) Ba (Mg 1/3 Nb 2/3 )O 3 microwave ceramics using extended x-ray absorption fine structure method

AU - Chang, P. J.

AU - Chia, Chi-Ta

AU - Lin, I. N.

AU - Lee, J. F.

AU - Lin, C. M.

AU - Wu, K. T.

PY - 2006/6/12

Y1 - 2006/6/12

N2 - The structures of Ta O6 and Nb O6 oxygen octahedra in xBa (Mg13 Ta23) O3 + (1-x) Ba (Mg13 Nb23) O3 perovskite ceramics with x=0, 0.25, 0.50, 0.75, and 1.0 were investigated by the extended x-ray absorption fine structure method. The decline in the microwave dielectric constant as x increases is caused mainly by the decrease of the mean volume of the oxygen octahedra, regardless of the 1:2 ordered structure and the distortion of the oxygen octahedron. The low Qf values of the Ta O6 and Nb O6 mixed samples are caused by not only the degrading of the 1:2 ordered structure but also the distortion of oxygen octahedral cages.

AB - The structures of Ta O6 and Nb O6 oxygen octahedra in xBa (Mg13 Ta23) O3 + (1-x) Ba (Mg13 Nb23) O3 perovskite ceramics with x=0, 0.25, 0.50, 0.75, and 1.0 were investigated by the extended x-ray absorption fine structure method. The decline in the microwave dielectric constant as x increases is caused mainly by the decrease of the mean volume of the oxygen octahedra, regardless of the 1:2 ordered structure and the distortion of the oxygen octahedron. The low Qf values of the Ta O6 and Nb O6 mixed samples are caused by not only the degrading of the 1:2 ordered structure but also the distortion of oxygen octahedral cages.

UR - http://www.scopus.com/inward/record.url?scp=33745203505&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33745203505&partnerID=8YFLogxK

U2 - 10.1063/1.2213514

DO - 10.1063/1.2213514

M3 - Article

AN - SCOPUS:33745203505

VL - 88

JO - Applied Physics Letters

JF - Applied Physics Letters

SN - 0003-6951

IS - 24

M1 - 242907

ER -