Characterizations of iron-containing clay modified electrodes and their applications for glucose sensing

Suh Ching Shyu, Chong Mou Wang

Research output: Contribution to journalArticle

30 Citations (Scopus)

Abstract

An amperometric biosensor was constructed on the basis of ruthenium purple-containing clay and glucose oxidase for the direct assay of glucose. These clay-modified electrodes were characterized by cyclic voltammetry and flow injection analysis techniques. The electrodes were very sensitive to the presence of glucose. Linear calibration curves between 10 μM and 15 mM with an electrode sensitivity of 3.88 μA/M and a detection limit of 10 μM were registered in aerated solutions (pH 5.1). Uric acid, ascorbic acid, and oxygen interfere very little with the detection of glucose. Long-term tests showed these clay electrodes were quite durable, e.g., the electrode sensitivity only decreases by ca. 25% over a period of six weeks.

Original languageEnglish
Pages (from-to)154-158
Number of pages5
JournalJournal of the Electrochemical Society
Volume145
Issue number1
DOIs
Publication statusPublished - 1998 Jan 1

Fingerprint

glucose
clays
Glucose
Clay
Iron
iron
Electrodes
electrodes
uric acid
Glucose Oxidase
Glucose oxidase
Ruthenium
ascorbic acid
Ascorbic acid
oxidase
sensitivity
Uric Acid
bioinstrumentation
Biosensors
ruthenium

ASJC Scopus subject areas

  • Electronic, Optical and Magnetic Materials
  • Renewable Energy, Sustainability and the Environment
  • Condensed Matter Physics
  • Surfaces, Coatings and Films
  • Electrochemistry
  • Materials Chemistry

Cite this

Characterizations of iron-containing clay modified electrodes and their applications for glucose sensing. / Shyu, Suh Ching; Wang, Chong Mou.

In: Journal of the Electrochemical Society, Vol. 145, No. 1, 01.01.1998, p. 154-158.

Research output: Contribution to journalArticle

@article{1b91b703eda8475d9cabafa0339fe986,
title = "Characterizations of iron-containing clay modified electrodes and their applications for glucose sensing",
abstract = "An amperometric biosensor was constructed on the basis of ruthenium purple-containing clay and glucose oxidase for the direct assay of glucose. These clay-modified electrodes were characterized by cyclic voltammetry and flow injection analysis techniques. The electrodes were very sensitive to the presence of glucose. Linear calibration curves between 10 μM and 15 mM with an electrode sensitivity of 3.88 μA/M and a detection limit of 10 μM were registered in aerated solutions (pH 5.1). Uric acid, ascorbic acid, and oxygen interfere very little with the detection of glucose. Long-term tests showed these clay electrodes were quite durable, e.g., the electrode sensitivity only decreases by ca. 25{\%} over a period of six weeks.",
author = "Shyu, {Suh Ching} and Wang, {Chong Mou}",
year = "1998",
month = "1",
day = "1",
doi = "10.1149/1.1838228",
language = "English",
volume = "145",
pages = "154--158",
journal = "Journal of the Electrochemical Society",
issn = "0013-4651",
publisher = "Electrochemical Society, Inc.",
number = "1",

}

TY - JOUR

T1 - Characterizations of iron-containing clay modified electrodes and their applications for glucose sensing

AU - Shyu, Suh Ching

AU - Wang, Chong Mou

PY - 1998/1/1

Y1 - 1998/1/1

N2 - An amperometric biosensor was constructed on the basis of ruthenium purple-containing clay and glucose oxidase for the direct assay of glucose. These clay-modified electrodes were characterized by cyclic voltammetry and flow injection analysis techniques. The electrodes were very sensitive to the presence of glucose. Linear calibration curves between 10 μM and 15 mM with an electrode sensitivity of 3.88 μA/M and a detection limit of 10 μM were registered in aerated solutions (pH 5.1). Uric acid, ascorbic acid, and oxygen interfere very little with the detection of glucose. Long-term tests showed these clay electrodes were quite durable, e.g., the electrode sensitivity only decreases by ca. 25% over a period of six weeks.

AB - An amperometric biosensor was constructed on the basis of ruthenium purple-containing clay and glucose oxidase for the direct assay of glucose. These clay-modified electrodes were characterized by cyclic voltammetry and flow injection analysis techniques. The electrodes were very sensitive to the presence of glucose. Linear calibration curves between 10 μM and 15 mM with an electrode sensitivity of 3.88 μA/M and a detection limit of 10 μM were registered in aerated solutions (pH 5.1). Uric acid, ascorbic acid, and oxygen interfere very little with the detection of glucose. Long-term tests showed these clay electrodes were quite durable, e.g., the electrode sensitivity only decreases by ca. 25% over a period of six weeks.

UR - http://www.scopus.com/inward/record.url?scp=0031673811&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0031673811&partnerID=8YFLogxK

U2 - 10.1149/1.1838228

DO - 10.1149/1.1838228

M3 - Article

VL - 145

SP - 154

EP - 158

JO - Journal of the Electrochemical Society

JF - Journal of the Electrochemical Society

SN - 0013-4651

IS - 1

ER -