Biomechanical evaluation of cervical spine fixation after healing in a destabilized cervical spine model in sheep: A comparison of the anterior plating and posterior wiring techniques

Ming Yang Lee, Guan Liang Chang, Jia Hao Chang, Yu Chang Hung, Ching Hong Chang, E. Jian Lee*

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

5 Citations (Scopus)

Abstract

BACKGROUND: We conducted biomechanical evaluation of the anterior plating and posterior wiring techniques for cervical spine stabilization after a course of healing in sheep. METHODS: Seventeen sheep were included, and six of which underwent sham operations (group A, n ≤ 6). The other eleven received complete C2-C3 destabilization, followed by intervertebral bone grafting and cervical stabilization either with anterior plating (group B, n ≤ 5) or posterior wiring (group C, n ≤ 6) techniques. These animals were killed 6 months later. Ligamentous spines (C1-C5) were subjected to the relevantly applied loads. The load-deformation data of the C2-C3 and C3-C4 functional units were recorded and analyzed. RESULTS: At the C2-C3 functional unit, group B had the least motion ranges in flexion, lateral bending, and rotation loads than did the other two groups. Significantly smaller motion ranges of lateral bending and rotation loads were found in group B than in group C (p < 0.05). Compared with group A, group C had a decreased motion range in flexion load but showed increased motion range in rotation load. Consequently, group B had superior intervertebral fusion and less osteophyte than did group C. At the C3-C4 functional unit, group B showed significantly decreased motion ranges in extension and lateral bending loads (p < 0.05), while group C did not. CONCLUSION: The results indicated that the anterior plate-stabilized spines were more stable over time than did the posterior-wired spines. This biomechanical advantage eventually resulted in superior intervertebral fusion masses in the former, although it also induced a slightly decreased motion range at the contiguous functional unit. In exclusively posterior wired-spines, the weakness for opposing rotation loads might contribute to the formation of osteophytes at the fusion functional unit. These data point out that the mode and stability of implant fixation systems greatly influence the biomechanical redistribution and bone-adaptive remodeling process during healing, which are closely related to the bone graft maturation and osteophytic formations at the fusion level and the occurrence of stiffening problems at the contiguous levels.

Original languageEnglish
Pages (from-to)1307-1314
Number of pages8
JournalJournal of Trauma - Injury, Infection and Critical Care
Volume60
Issue number6
DOIs
Publication statusPublished - 2006 Jun
Externally publishedYes

Keywords

  • Anterior plating
  • Bone-adaptive remodeling
  • Kinematics
  • Posterior wiring

ASJC Scopus subject areas

  • Surgery
  • Critical Care and Intensive Care Medicine

Fingerprint

Dive into the research topics of 'Biomechanical evaluation of cervical spine fixation after healing in a destabilized cervical spine model in sheep: A comparison of the anterior plating and posterior wiring techniques'. Together they form a unique fingerprint.

Cite this