Abstract

In the hopes of reducing the unpredictability associated with refractive surgical procedures and ultimately improving surgical techniques, many investigators have attempted to determine the elastic moduli of the cornea. Techniques such as stress-strain tests of corneal strips and the measurement of mercury drop displacement in a whole eye under increasing pressure have resulted in a range of values for Young's modulus from 105 to 107 N m-2. Both of these methods are limited because these mechanical tests cannot be performed in the physiological state and because of the large amount of force applied during testing. We used an ultrasonic technique to determine the elastic moduli of the human cornea. Two groups of six corneas prepared under different conditions (in saline and in dextran) were examined separately and the shear waves were generated and detected in these 12 human eye bank eyes. All the waveforms were digitized and saved in files of binary format. Fast Fourier transformation (FFT) was applied to calculate the speed and attenuation of the shear wave. Using the resulting wave speeds and attenuation coefficients, the Young's moduli of the corneal samples were calculated as (5.3 ± 1.1) × 106 N m-2 and (2.0 ± 1.0) × 107 N m-2 for cornea samples prepared in saline and in dextran at 2.25 MHz, respectively.

Original languageEnglish
Pages (from-to)1633-1636
Number of pages4
JournalJournal of Biomechanics
Volume29
Issue number12
DOIs
Publication statusPublished - 1996 Dec

Fingerprint

Elastic Modulus
Ultrasonics
Cornea
dextran - saline drug combination
Elastic moduli
Dextran
Shear waves
Eye Banks
Refractive Surgical Procedures
Mercury
Exercise Test
Research Personnel
Pressure
Testing

Keywords

  • Attenuation
  • Shear modulus
  • Shear wave
  • Wave speed
  • Young's modulus

ASJC Scopus subject areas

  • Biophysics
  • Orthopedics and Sports Medicine
  • Biomedical Engineering
  • Rehabilitation

Cite this

An ultrasonic technique for the measurement of the elastic moduli of human cornea. / Wang, Hsichun; Prendiville, Paul L.; McDonnell, Peter J.; Chang, Wenji V.

In: Journal of Biomechanics, Vol. 29, No. 12, 12.1996, p. 1633-1636.

Research output: Contribution to journalArticle

Wang, Hsichun ; Prendiville, Paul L. ; McDonnell, Peter J. ; Chang, Wenji V. / An ultrasonic technique for the measurement of the elastic moduli of human cornea. In: Journal of Biomechanics. 1996 ; Vol. 29, No. 12. pp. 1633-1636.
@article{e3dba5d1997a48c6acc63a92afb39127,
title = "An ultrasonic technique for the measurement of the elastic moduli of human cornea",
abstract = "In the hopes of reducing the unpredictability associated with refractive surgical procedures and ultimately improving surgical techniques, many investigators have attempted to determine the elastic moduli of the cornea. Techniques such as stress-strain tests of corneal strips and the measurement of mercury drop displacement in a whole eye under increasing pressure have resulted in a range of values for Young's modulus from 105 to 107 N m-2. Both of these methods are limited because these mechanical tests cannot be performed in the physiological state and because of the large amount of force applied during testing. We used an ultrasonic technique to determine the elastic moduli of the human cornea. Two groups of six corneas prepared under different conditions (in saline and in dextran) were examined separately and the shear waves were generated and detected in these 12 human eye bank eyes. All the waveforms were digitized and saved in files of binary format. Fast Fourier transformation (FFT) was applied to calculate the speed and attenuation of the shear wave. Using the resulting wave speeds and attenuation coefficients, the Young's moduli of the corneal samples were calculated as (5.3 ± 1.1) × 106 N m-2 and (2.0 ± 1.0) × 107 N m-2 for cornea samples prepared in saline and in dextran at 2.25 MHz, respectively.",
keywords = "Attenuation, Shear modulus, Shear wave, Wave speed, Young's modulus",
author = "Hsichun Wang and Prendiville, {Paul L.} and McDonnell, {Peter J.} and Chang, {Wenji V.}",
year = "1996",
month = "12",
doi = "10.1016/S0021-9290(96)80017-0",
language = "English",
volume = "29",
pages = "1633--1636",
journal = "Journal of Biomechanics",
issn = "0021-9290",
publisher = "Elsevier Limited",
number = "12",

}

TY - JOUR

T1 - An ultrasonic technique for the measurement of the elastic moduli of human cornea

AU - Wang, Hsichun

AU - Prendiville, Paul L.

AU - McDonnell, Peter J.

AU - Chang, Wenji V.

PY - 1996/12

Y1 - 1996/12

N2 - In the hopes of reducing the unpredictability associated with refractive surgical procedures and ultimately improving surgical techniques, many investigators have attempted to determine the elastic moduli of the cornea. Techniques such as stress-strain tests of corneal strips and the measurement of mercury drop displacement in a whole eye under increasing pressure have resulted in a range of values for Young's modulus from 105 to 107 N m-2. Both of these methods are limited because these mechanical tests cannot be performed in the physiological state and because of the large amount of force applied during testing. We used an ultrasonic technique to determine the elastic moduli of the human cornea. Two groups of six corneas prepared under different conditions (in saline and in dextran) were examined separately and the shear waves were generated and detected in these 12 human eye bank eyes. All the waveforms were digitized and saved in files of binary format. Fast Fourier transformation (FFT) was applied to calculate the speed and attenuation of the shear wave. Using the resulting wave speeds and attenuation coefficients, the Young's moduli of the corneal samples were calculated as (5.3 ± 1.1) × 106 N m-2 and (2.0 ± 1.0) × 107 N m-2 for cornea samples prepared in saline and in dextran at 2.25 MHz, respectively.

AB - In the hopes of reducing the unpredictability associated with refractive surgical procedures and ultimately improving surgical techniques, many investigators have attempted to determine the elastic moduli of the cornea. Techniques such as stress-strain tests of corneal strips and the measurement of mercury drop displacement in a whole eye under increasing pressure have resulted in a range of values for Young's modulus from 105 to 107 N m-2. Both of these methods are limited because these mechanical tests cannot be performed in the physiological state and because of the large amount of force applied during testing. We used an ultrasonic technique to determine the elastic moduli of the human cornea. Two groups of six corneas prepared under different conditions (in saline and in dextran) were examined separately and the shear waves were generated and detected in these 12 human eye bank eyes. All the waveforms were digitized and saved in files of binary format. Fast Fourier transformation (FFT) was applied to calculate the speed and attenuation of the shear wave. Using the resulting wave speeds and attenuation coefficients, the Young's moduli of the corneal samples were calculated as (5.3 ± 1.1) × 106 N m-2 and (2.0 ± 1.0) × 107 N m-2 for cornea samples prepared in saline and in dextran at 2.25 MHz, respectively.

KW - Attenuation

KW - Shear modulus

KW - Shear wave

KW - Wave speed

KW - Young's modulus

UR - http://www.scopus.com/inward/record.url?scp=0030561003&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0030561003&partnerID=8YFLogxK

U2 - 10.1016/S0021-9290(96)80017-0

DO - 10.1016/S0021-9290(96)80017-0

M3 - Article

C2 - 8945664

AN - SCOPUS:0030561003

VL - 29

SP - 1633

EP - 1636

JO - Journal of Biomechanics

JF - Journal of Biomechanics

SN - 0021-9290

IS - 12

ER -