An analysis of Maillard reaction products in ethanolic glucose-glycine solution

Szu Chuan Shen, Kou Chan Tseng, James Swi Bea Wu

Research output: Contribution to journalArticle

32 Citations (Scopus)

Abstract

The present study compared the Maillard reaction products in ethanolic and aqueous glucose-glycine solutions. The pH 4.3, 0.2 M glucose-0.2 M glycine solutions were prepared and heated. HPLC-DAD (diode array detection) was then used to analyse the browned solutions, the ethyl acetate extracts of the solutions, and the coloured bands in TLC of the extracts. HMF (5-hydroxymethyl-2-furaldehyde) was found in both of the browned aqueous and ethanolic solutions, while 2-hydroxymethylfuran was found only in the browned ethanolic solution. HMF and 2-acetylpyrrole appear in the ethyl acetate extract of both systems, whereas 2-acetyl-1-methylpyrrole is present only in the extract of the ethanolic solution. The difference in profile of products in the aqueous and the ethanolic solutions indicates that the mechanisms of Maillard reaction in these two systems are not exactly the same.

Original languageEnglish
Pages (from-to)281-287
Number of pages7
JournalFood Chemistry
Volume102
Issue number1
DOIs
Publication statusPublished - 2007 Jan 1

Fingerprint

Maillard Reaction
Maillard reaction products
Reaction products
Glycine
Glucose
glucose
hydroxymethylfurfural
extracts
water
Maillard reaction
Diodes
High Pressure Liquid Chromatography

Keywords

  • 5-hydroxymethyl-2-furaldehyde
  • Diode array detection
  • Ethanolic
  • Glucose-glycine
  • Maillard reaction

ASJC Scopus subject areas

  • Analytical Chemistry
  • Food Science

Cite this

An analysis of Maillard reaction products in ethanolic glucose-glycine solution. / Shen, Szu Chuan; Tseng, Kou Chan; Wu, James Swi Bea.

In: Food Chemistry, Vol. 102, No. 1, 01.01.2007, p. 281-287.

Research output: Contribution to journalArticle

Shen, Szu Chuan ; Tseng, Kou Chan ; Wu, James Swi Bea. / An analysis of Maillard reaction products in ethanolic glucose-glycine solution. In: Food Chemistry. 2007 ; Vol. 102, No. 1. pp. 281-287.
@article{bdd9f6940522429b891d40fc8a54343b,
title = "An analysis of Maillard reaction products in ethanolic glucose-glycine solution",
abstract = "The present study compared the Maillard reaction products in ethanolic and aqueous glucose-glycine solutions. The pH 4.3, 0.2 M glucose-0.2 M glycine solutions were prepared and heated. HPLC-DAD (diode array detection) was then used to analyse the browned solutions, the ethyl acetate extracts of the solutions, and the coloured bands in TLC of the extracts. HMF (5-hydroxymethyl-2-furaldehyde) was found in both of the browned aqueous and ethanolic solutions, while 2-hydroxymethylfuran was found only in the browned ethanolic solution. HMF and 2-acetylpyrrole appear in the ethyl acetate extract of both systems, whereas 2-acetyl-1-methylpyrrole is present only in the extract of the ethanolic solution. The difference in profile of products in the aqueous and the ethanolic solutions indicates that the mechanisms of Maillard reaction in these two systems are not exactly the same.",
keywords = "5-hydroxymethyl-2-furaldehyde, Diode array detection, Ethanolic, Glucose-glycine, Maillard reaction",
author = "Shen, {Szu Chuan} and Tseng, {Kou Chan} and Wu, {James Swi Bea}",
year = "2007",
month = "1",
day = "1",
doi = "10.1016/j.foodchem.2006.05.018",
language = "English",
volume = "102",
pages = "281--287",
journal = "Food Chemistry",
issn = "0308-8146",
publisher = "Elsevier Limited",
number = "1",

}

TY - JOUR

T1 - An analysis of Maillard reaction products in ethanolic glucose-glycine solution

AU - Shen, Szu Chuan

AU - Tseng, Kou Chan

AU - Wu, James Swi Bea

PY - 2007/1/1

Y1 - 2007/1/1

N2 - The present study compared the Maillard reaction products in ethanolic and aqueous glucose-glycine solutions. The pH 4.3, 0.2 M glucose-0.2 M glycine solutions were prepared and heated. HPLC-DAD (diode array detection) was then used to analyse the browned solutions, the ethyl acetate extracts of the solutions, and the coloured bands in TLC of the extracts. HMF (5-hydroxymethyl-2-furaldehyde) was found in both of the browned aqueous and ethanolic solutions, while 2-hydroxymethylfuran was found only in the browned ethanolic solution. HMF and 2-acetylpyrrole appear in the ethyl acetate extract of both systems, whereas 2-acetyl-1-methylpyrrole is present only in the extract of the ethanolic solution. The difference in profile of products in the aqueous and the ethanolic solutions indicates that the mechanisms of Maillard reaction in these two systems are not exactly the same.

AB - The present study compared the Maillard reaction products in ethanolic and aqueous glucose-glycine solutions. The pH 4.3, 0.2 M glucose-0.2 M glycine solutions were prepared and heated. HPLC-DAD (diode array detection) was then used to analyse the browned solutions, the ethyl acetate extracts of the solutions, and the coloured bands in TLC of the extracts. HMF (5-hydroxymethyl-2-furaldehyde) was found in both of the browned aqueous and ethanolic solutions, while 2-hydroxymethylfuran was found only in the browned ethanolic solution. HMF and 2-acetylpyrrole appear in the ethyl acetate extract of both systems, whereas 2-acetyl-1-methylpyrrole is present only in the extract of the ethanolic solution. The difference in profile of products in the aqueous and the ethanolic solutions indicates that the mechanisms of Maillard reaction in these two systems are not exactly the same.

KW - 5-hydroxymethyl-2-furaldehyde

KW - Diode array detection

KW - Ethanolic

KW - Glucose-glycine

KW - Maillard reaction

UR - http://www.scopus.com/inward/record.url?scp=33751527023&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33751527023&partnerID=8YFLogxK

U2 - 10.1016/j.foodchem.2006.05.018

DO - 10.1016/j.foodchem.2006.05.018

M3 - Article

AN - SCOPUS:33751527023

VL - 102

SP - 281

EP - 287

JO - Food Chemistry

JF - Food Chemistry

SN - 0308-8146

IS - 1

ER -