Aluminum based metal-organic framework-polymer monolith in solid-phase microextraction of penicillins in river water and milk samples

Stephen Lirio, Wan Ling Liu, Chen Lan Lin, Chia Her Lin*, Hsi Ya Huang

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

105 Citations (Scopus)

Abstract

In this study, aluminum based metal-organic framework (Al-MOF)-organic polymer monoliths were prepared via microwave-assisted polymerization of ethylene dimethacrylate (EDMA), butyl methacrylate (BMA) with different weight percentages of Al-MOF (MIL-53; 37.5-62.5%) and subsequently utilized as sorbent in solid-phase microextraction (SPME) of penicillins (penicillin G, penicillin V, oxacillin, cloxacillin, dicloxacillin, nafcillin). The Al-MOF-polymer was characterized using Fourier transform infrared (FTIR) spectroscopy, powder X-ray diffraction (XRD), scanning electron microscopy (SEM) and SEM-energy-dispersive X-ray spectroscopy (SEM-EDS) to clarify the retained crystalline structure well as the homogeneous dispersion of Al-MOF (MIL-53) in polymer monolith. The developed Al-MOF-polymer (MIL-53) monolithic column was evaluated according to its extraction recovery of penicillins. Several parameters affecting the extraction recoveries of penicillins using fabricated Al-MOF-polymer (MIL-53) monolithic column including different MIL-53 weight percentages, column length, pH, desorption solvent, and mobile phase flow rate were investigated. For comparison, different Al-based MOFs (MIL-68, CYCU-4 and DUT-5) were fabricated using the optimized condition for MIL-53-polymer (sample matrix at pH 3, 200μL desorption volume using methanol, 37.5% of MOF, 4-cm column length at 0.100mLmin-1 flow rate). Among all the Al-MOF-polymers, MIL-53(Al)-polymer still afforded the best extraction recovery for penicillins ranging from 90.5 to 95.7% for intra-day with less than 3.5% relative standard deviations (RSDs) and inter-day precision were in the range of 90.7-97.6% with less than 4.2% RSDs. Meanwhile, the recoveries for column-to-column were in the range of 89.5-93.5% (<3.4% RSDs) while 88.5-90.5% (<5.8% RSDs) for batch-to-batch (n=3). Under the optimal conditions, the limit of detections were in the range of 0.06-0.26μgL-1 and limit of quantifications between 0.20 and 0.87μgL-1. Finally, the MIL-53-polymer was applied for the extraction of penicillin in river water and milk by spiking trace-level penicillin for as low as 50μgL-1 and 100μgL-1 with recoveries ranging from 80.8% to 90.9% (<6.7% RSDs) in river water and 81.1% to 100.7% (<7.1% RSDs) in milk sample, respectively.

Original languageEnglish
Pages (from-to)236-245
Number of pages10
JournalJournal of Chromatography A
Volume1428
DOIs
Publication statusPublished - 2016 Jan 8
Externally publishedYes

Keywords

  • Metal-organic framework (MOF)
  • Milk
  • Penicillin
  • Polymer monolithic column
  • Solid-phase microextraction (SPME)

ASJC Scopus subject areas

  • Analytical Chemistry
  • Biochemistry
  • Organic Chemistry

Fingerprint

Dive into the research topics of 'Aluminum based metal-organic framework-polymer monolith in solid-phase microextraction of penicillins in river water and milk samples'. Together they form a unique fingerprint.

Cite this