Biomechanical testing of the spine has been performed to help understand the normal function of the spine as well as to evaluate the effects of injury and surgical procedures on spinal behavior. The purpose of this study was to develop a tester which could produce continuous loading for the entire range of motion of the spine. The spinal tester frame was built out of modular aluminum extrusions and servo motors combined with a planetary reduction gearbox used to drive the apparatus. A self-written software package running in Borland C ++ Builder provided an interface allowing the user to define desired motions and collect the load and displacement data. A polyurethane tube used for testing the accuracy of the spinal tester was rotated at a constant speed of l°/sec until a maximum loading of 2 Nm was achieved in right-left lateral bending, flexion-extension and right-left axial rotation in sequence. A spinal unit function from a sheep spine was also tested in the same procedures for evaluating the changes in range of motion and neutral zone after discectomy and implantation. The results showed that the errors between recorded value and calculated value of the polyurethane tube were 2.16%, 2.66% and 1.72% in flexion-extension, lateral bending and axial rotation, respectively. In the sheep spine, the range of motion and neutral zone were increased after discectomy and recovered after implantation in flexion-extension and lateral bending. In conclusion, an apparatus producing cyclic continuous pure moment movement was built. This multi-directional spinal tester was an effective and practical machine in the biomechanical study of spine.

Original languageEnglish
Pages (from-to)7-13
Number of pages7
JournalJournal of Medical and Biological Engineering
Volume29
Issue number1
Publication statusPublished - 2009 Mar

Fingerprint

Biomechanics
Biomechanical Phenomena
Polyurethanes
Spine
Testing
Articular Range of Motion
Software packages
Extrusion
Diskectomy
Aluminum
Sheep
Intraoperative Complications
Running
Direction compound
Software

Keywords

  • Pure moment
  • Range of motion
  • Spinal biomechanics

ASJC Scopus subject areas

  • Biomedical Engineering
  • Medicine(all)

Cite this

A new multi-direction tester for evaluation of the spinal biomechanics. / Chang, Ti Sheng; Cheng, Ching Wei; Wang, Chien Shiung; Chen, Hung Yi; Chang, Jia Hao.

In: Journal of Medical and Biological Engineering, Vol. 29, No. 1, 03.2009, p. 7-13.

Research output: Contribution to journalArticle

Chang, Ti Sheng ; Cheng, Ching Wei ; Wang, Chien Shiung ; Chen, Hung Yi ; Chang, Jia Hao. / A new multi-direction tester for evaluation of the spinal biomechanics. In: Journal of Medical and Biological Engineering. 2009 ; Vol. 29, No. 1. pp. 7-13.
@article{e1707bb873cf4b9799fc639087742da6,
title = "A new multi-direction tester for evaluation of the spinal biomechanics",
abstract = "Biomechanical testing of the spine has been performed to help understand the normal function of the spine as well as to evaluate the effects of injury and surgical procedures on spinal behavior. The purpose of this study was to develop a tester which could produce continuous loading for the entire range of motion of the spine. The spinal tester frame was built out of modular aluminum extrusions and servo motors combined with a planetary reduction gearbox used to drive the apparatus. A self-written software package running in Borland C ++ Builder provided an interface allowing the user to define desired motions and collect the load and displacement data. A polyurethane tube used for testing the accuracy of the spinal tester was rotated at a constant speed of l°/sec until a maximum loading of 2 Nm was achieved in right-left lateral bending, flexion-extension and right-left axial rotation in sequence. A spinal unit function from a sheep spine was also tested in the same procedures for evaluating the changes in range of motion and neutral zone after discectomy and implantation. The results showed that the errors between recorded value and calculated value of the polyurethane tube were 2.16{\%}, 2.66{\%} and 1.72{\%} in flexion-extension, lateral bending and axial rotation, respectively. In the sheep spine, the range of motion and neutral zone were increased after discectomy and recovered after implantation in flexion-extension and lateral bending. In conclusion, an apparatus producing cyclic continuous pure moment movement was built. This multi-directional spinal tester was an effective and practical machine in the biomechanical study of spine.",
keywords = "Pure moment, Range of motion, Spinal biomechanics",
author = "Chang, {Ti Sheng} and Cheng, {Ching Wei} and Wang, {Chien Shiung} and Chen, {Hung Yi} and Chang, {Jia Hao}",
year = "2009",
month = "3",
language = "English",
volume = "29",
pages = "7--13",
journal = "Journal of Medical and Biological Engineering",
issn = "1609-0985",
publisher = "中華民國生物醫學工程學會",
number = "1",

}

TY - JOUR

T1 - A new multi-direction tester for evaluation of the spinal biomechanics

AU - Chang, Ti Sheng

AU - Cheng, Ching Wei

AU - Wang, Chien Shiung

AU - Chen, Hung Yi

AU - Chang, Jia Hao

PY - 2009/3

Y1 - 2009/3

N2 - Biomechanical testing of the spine has been performed to help understand the normal function of the spine as well as to evaluate the effects of injury and surgical procedures on spinal behavior. The purpose of this study was to develop a tester which could produce continuous loading for the entire range of motion of the spine. The spinal tester frame was built out of modular aluminum extrusions and servo motors combined with a planetary reduction gearbox used to drive the apparatus. A self-written software package running in Borland C ++ Builder provided an interface allowing the user to define desired motions and collect the load and displacement data. A polyurethane tube used for testing the accuracy of the spinal tester was rotated at a constant speed of l°/sec until a maximum loading of 2 Nm was achieved in right-left lateral bending, flexion-extension and right-left axial rotation in sequence. A spinal unit function from a sheep spine was also tested in the same procedures for evaluating the changes in range of motion and neutral zone after discectomy and implantation. The results showed that the errors between recorded value and calculated value of the polyurethane tube were 2.16%, 2.66% and 1.72% in flexion-extension, lateral bending and axial rotation, respectively. In the sheep spine, the range of motion and neutral zone were increased after discectomy and recovered after implantation in flexion-extension and lateral bending. In conclusion, an apparatus producing cyclic continuous pure moment movement was built. This multi-directional spinal tester was an effective and practical machine in the biomechanical study of spine.

AB - Biomechanical testing of the spine has been performed to help understand the normal function of the spine as well as to evaluate the effects of injury and surgical procedures on spinal behavior. The purpose of this study was to develop a tester which could produce continuous loading for the entire range of motion of the spine. The spinal tester frame was built out of modular aluminum extrusions and servo motors combined with a planetary reduction gearbox used to drive the apparatus. A self-written software package running in Borland C ++ Builder provided an interface allowing the user to define desired motions and collect the load and displacement data. A polyurethane tube used for testing the accuracy of the spinal tester was rotated at a constant speed of l°/sec until a maximum loading of 2 Nm was achieved in right-left lateral bending, flexion-extension and right-left axial rotation in sequence. A spinal unit function from a sheep spine was also tested in the same procedures for evaluating the changes in range of motion and neutral zone after discectomy and implantation. The results showed that the errors between recorded value and calculated value of the polyurethane tube were 2.16%, 2.66% and 1.72% in flexion-extension, lateral bending and axial rotation, respectively. In the sheep spine, the range of motion and neutral zone were increased after discectomy and recovered after implantation in flexion-extension and lateral bending. In conclusion, an apparatus producing cyclic continuous pure moment movement was built. This multi-directional spinal tester was an effective and practical machine in the biomechanical study of spine.

KW - Pure moment

KW - Range of motion

KW - Spinal biomechanics

UR - http://www.scopus.com/inward/record.url?scp=64949162672&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=64949162672&partnerID=8YFLogxK

M3 - Article

VL - 29

SP - 7

EP - 13

JO - Journal of Medical and Biological Engineering

JF - Journal of Medical and Biological Engineering

SN - 1609-0985

IS - 1

ER -