A highly sensitive YBCO serial SQUID magnetometer with a flux focuser

C. H. Wu, M. H. Hsu, K. L. Chen, J. C. Chen, J. T. Jeng, T. S. Lai, Herng Er Horng, Hong Chang Yang

Research output: Contribution to journalArticle

14 Citations (Scopus)

Abstract

We have designed and fabricated a low noise, high Tc superconducting quantum interference device (SQUID) magnetometer with an improved yield. In order to reduce the field noise level of the magnetometer, we increased the voltage modulation depth with a series SQUID array and enhanced the effective area with a flux focuser. Ten washer-type SQUIDs were connected in series, thereby increasing the voltage flux transfer function by a factor of 10. An enhancement in effective area by a factor of 5 was achieved by coupling the 10-SQUID array to a single-layered flux focuser. For the directly coupled SQUID array magnetometer, the yield was improved by selecting the best SQUIDs to have in series in order to reduce the flux noise. The magnetic field sensitivity of 40 fT Hz-1/2 in the white regime and 100 fT Hz -1/2 at 1 Hz is demonstrated by using a single layer of high T c film. The proposed high yield magnetometers would be suitable for building low noise multi-channel magnetocardiographs.

Original languageEnglish
Pages (from-to)S246-S250
JournalSuperconductor Science and Technology
Volume19
Issue number5
DOIs
Publication statusPublished - 2006 May 1

Fingerprint

SQUIDs
Magnetometers
magnetometers
Fluxes
interference
low noise
washers
electric potential
transfer functions
Washers
Electric potential
modulation
Transfer functions
augmentation
magnetic fields
Modulation
Magnetic fields

ASJC Scopus subject areas

  • Ceramics and Composites
  • Condensed Matter Physics
  • Metals and Alloys
  • Electrical and Electronic Engineering
  • Materials Chemistry

Cite this

Wu, C. H., Hsu, M. H., Chen, K. L., Chen, J. C., Jeng, J. T., Lai, T. S., ... Yang, H. C. (2006). A highly sensitive YBCO serial SQUID magnetometer with a flux focuser. Superconductor Science and Technology, 19(5), S246-S250. https://doi.org/10.1088/0953-2048/19/5/S17

A highly sensitive YBCO serial SQUID magnetometer with a flux focuser. / Wu, C. H.; Hsu, M. H.; Chen, K. L.; Chen, J. C.; Jeng, J. T.; Lai, T. S.; Horng, Herng Er; Yang, Hong Chang.

In: Superconductor Science and Technology, Vol. 19, No. 5, 01.05.2006, p. S246-S250.

Research output: Contribution to journalArticle

Wu, CH, Hsu, MH, Chen, KL, Chen, JC, Jeng, JT, Lai, TS, Horng, HE & Yang, HC 2006, 'A highly sensitive YBCO serial SQUID magnetometer with a flux focuser', Superconductor Science and Technology, vol. 19, no. 5, pp. S246-S250. https://doi.org/10.1088/0953-2048/19/5/S17
Wu, C. H. ; Hsu, M. H. ; Chen, K. L. ; Chen, J. C. ; Jeng, J. T. ; Lai, T. S. ; Horng, Herng Er ; Yang, Hong Chang. / A highly sensitive YBCO serial SQUID magnetometer with a flux focuser. In: Superconductor Science and Technology. 2006 ; Vol. 19, No. 5. pp. S246-S250.
@article{fe8a5d6de6c64a0496371a3142035e5f,
title = "A highly sensitive YBCO serial SQUID magnetometer with a flux focuser",
abstract = "We have designed and fabricated a low noise, high Tc superconducting quantum interference device (SQUID) magnetometer with an improved yield. In order to reduce the field noise level of the magnetometer, we increased the voltage modulation depth with a series SQUID array and enhanced the effective area with a flux focuser. Ten washer-type SQUIDs were connected in series, thereby increasing the voltage flux transfer function by a factor of 10. An enhancement in effective area by a factor of 5 was achieved by coupling the 10-SQUID array to a single-layered flux focuser. For the directly coupled SQUID array magnetometer, the yield was improved by selecting the best SQUIDs to have in series in order to reduce the flux noise. The magnetic field sensitivity of 40 fT Hz-1/2 in the white regime and 100 fT Hz -1/2 at 1 Hz is demonstrated by using a single layer of high T c film. The proposed high yield magnetometers would be suitable for building low noise multi-channel magnetocardiographs.",
author = "Wu, {C. H.} and Hsu, {M. H.} and Chen, {K. L.} and Chen, {J. C.} and Jeng, {J. T.} and Lai, {T. S.} and Horng, {Herng Er} and Yang, {Hong Chang}",
year = "2006",
month = "5",
day = "1",
doi = "10.1088/0953-2048/19/5/S17",
language = "English",
volume = "19",
pages = "S246--S250",
journal = "Superconductor Science and Technology",
issn = "0953-2048",
publisher = "IOP Publishing Ltd.",
number = "5",

}

TY - JOUR

T1 - A highly sensitive YBCO serial SQUID magnetometer with a flux focuser

AU - Wu, C. H.

AU - Hsu, M. H.

AU - Chen, K. L.

AU - Chen, J. C.

AU - Jeng, J. T.

AU - Lai, T. S.

AU - Horng, Herng Er

AU - Yang, Hong Chang

PY - 2006/5/1

Y1 - 2006/5/1

N2 - We have designed and fabricated a low noise, high Tc superconducting quantum interference device (SQUID) magnetometer with an improved yield. In order to reduce the field noise level of the magnetometer, we increased the voltage modulation depth with a series SQUID array and enhanced the effective area with a flux focuser. Ten washer-type SQUIDs were connected in series, thereby increasing the voltage flux transfer function by a factor of 10. An enhancement in effective area by a factor of 5 was achieved by coupling the 10-SQUID array to a single-layered flux focuser. For the directly coupled SQUID array magnetometer, the yield was improved by selecting the best SQUIDs to have in series in order to reduce the flux noise. The magnetic field sensitivity of 40 fT Hz-1/2 in the white regime and 100 fT Hz -1/2 at 1 Hz is demonstrated by using a single layer of high T c film. The proposed high yield magnetometers would be suitable for building low noise multi-channel magnetocardiographs.

AB - We have designed and fabricated a low noise, high Tc superconducting quantum interference device (SQUID) magnetometer with an improved yield. In order to reduce the field noise level of the magnetometer, we increased the voltage modulation depth with a series SQUID array and enhanced the effective area with a flux focuser. Ten washer-type SQUIDs were connected in series, thereby increasing the voltage flux transfer function by a factor of 10. An enhancement in effective area by a factor of 5 was achieved by coupling the 10-SQUID array to a single-layered flux focuser. For the directly coupled SQUID array magnetometer, the yield was improved by selecting the best SQUIDs to have in series in order to reduce the flux noise. The magnetic field sensitivity of 40 fT Hz-1/2 in the white regime and 100 fT Hz -1/2 at 1 Hz is demonstrated by using a single layer of high T c film. The proposed high yield magnetometers would be suitable for building low noise multi-channel magnetocardiographs.

UR - http://www.scopus.com/inward/record.url?scp=33645538515&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33645538515&partnerID=8YFLogxK

U2 - 10.1088/0953-2048/19/5/S17

DO - 10.1088/0953-2048/19/5/S17

M3 - Article

AN - SCOPUS:33645538515

VL - 19

SP - S246-S250

JO - Superconductor Science and Technology

JF - Superconductor Science and Technology

SN - 0953-2048

IS - 5

ER -