不同勁度網球拍對恢復係數的影響

蘇 榮立(Rong-Lih Su), 相 子元(Tzyy-Yuan Shiang)

Research output: Contribution to journalArticle

Abstract

The purpose of this pilot study was to investigate the correlation between the stiffness of tennis racket and the coefficient of restitution(COR).The tennis racket was fixed in a clamp and the tennis ball was controlled to hit the racket with a vertical impact at certain speed(approximate 20m/sec). NAC high speed camera (1000 frame/sec) was used to record the whole experimental procedure. The video tape was then digitized using Peak Performance System After statistical analysis, the results showed: The COR of high stiffness racket (stiffness=70)、medium stiffness racket(stiffness=60)and low stiffness racket (stiffness=50)are 0.604, 0.546, 0.472, respectively. According to the ANOVA, the COR of different stiffness rackets are significantly different (stiffness 70>stiffness 60>stiffness 50).
Original languageChinese
Pages (from-to)261-268
Number of pages8
Journal體育學報
Issue number20
DOIs
Publication statusPublished - 1995

Cite this

不同勁度網球拍對恢復係數的影響. / 蘇榮立(Rong-Lih Su); 相子元(Tzyy-Yuan Shiang).

In: 體育學報, No. 20, 1995, p. 261-268.

Research output: Contribution to journalArticle

蘇榮立(Rong-Lih Su) ; 相子元(Tzyy-Yuan Shiang). / 不同勁度網球拍對恢復係數的影響. In: 體育學報. 1995 ; No. 20. pp. 261-268.
@article{d42f605f31c04dd781d1e4c836cb8a0f,
title = "不同勁度網球拍對恢復係數的影響",
abstract = "The purpose of this pilot study was to investigate the correlation between the stiffness of tennis racket and the coefficient of restitution(COR).The tennis racket was fixed in a clamp and the tennis ball was controlled to hit the racket with a vertical impact at certain speed(approximate 20m/sec). NAC high speed camera (1000 frame/sec) was used to record the whole experimental procedure. The video tape was then digitized using Peak Performance System After statistical analysis, the results showed: The COR of high stiffness racket (stiffness=70)、medium stiffness racket(stiffness=60)and low stiffness racket (stiffness=50)are 0.604, 0.546, 0.472, respectively. According to the ANOVA, the COR of different stiffness rackets are significantly different (stiffness 70>stiffness 60>stiffness 50).",
keywords = "網球拍, 勁度, 生物力學, 器材, Tennis racket, Stiffness, Biomechanics, Equipment",
author = "蘇, {榮立(Rong-Lih Su)} and 相, {子元(Tzyy-Yuan Shiang)}",
year = "1995",
doi = "10.6222/pej.0020.199512.4023",
language = "Chinese",
pages = "261--268",
journal = "體育學報",
issn = "1024-7297",
publisher = "中華民國體育學會",
number = "20",

}

TY - JOUR

T1 - 不同勁度網球拍對恢復係數的影響

AU - 蘇, 榮立(Rong-Lih Su)

AU - 相, 子元(Tzyy-Yuan Shiang)

PY - 1995

Y1 - 1995

N2 - The purpose of this pilot study was to investigate the correlation between the stiffness of tennis racket and the coefficient of restitution(COR).The tennis racket was fixed in a clamp and the tennis ball was controlled to hit the racket with a vertical impact at certain speed(approximate 20m/sec). NAC high speed camera (1000 frame/sec) was used to record the whole experimental procedure. The video tape was then digitized using Peak Performance System After statistical analysis, the results showed: The COR of high stiffness racket (stiffness=70)、medium stiffness racket(stiffness=60)and low stiffness racket (stiffness=50)are 0.604, 0.546, 0.472, respectively. According to the ANOVA, the COR of different stiffness rackets are significantly different (stiffness 70>stiffness 60>stiffness 50).

AB - The purpose of this pilot study was to investigate the correlation between the stiffness of tennis racket and the coefficient of restitution(COR).The tennis racket was fixed in a clamp and the tennis ball was controlled to hit the racket with a vertical impact at certain speed(approximate 20m/sec). NAC high speed camera (1000 frame/sec) was used to record the whole experimental procedure. The video tape was then digitized using Peak Performance System After statistical analysis, the results showed: The COR of high stiffness racket (stiffness=70)、medium stiffness racket(stiffness=60)and low stiffness racket (stiffness=50)are 0.604, 0.546, 0.472, respectively. According to the ANOVA, the COR of different stiffness rackets are significantly different (stiffness 70>stiffness 60>stiffness 50).

KW - 網球拍

KW - 勁度

KW - 生物力學

KW - 器材

KW - Tennis racket

KW - Stiffness

KW - Biomechanics

KW - Equipment

U2 - 10.6222/pej.0020.199512.4023

DO - 10.6222/pej.0020.199512.4023

M3 - 文章

SP - 261

EP - 268

JO - 體育學報

JF - 體育學報

SN - 1024-7297

IS - 20

ER -